Troubleshooting

FAULT
No Sensor
0.0 ft/m
0.0
V=11.6

Low Voltage

0.0 ft/m
0.0
V=7.9
Overcurrent
0.0 ft/m
0.0
V=11.6
EV-020
ft
I=0.0
ft
I=0.0
ft
I=300.0
CAUSE
Though UP or DOWN
keys are pressed, the
instrument
doesn't
receive any signal from
the magnetic sensor for
more than 5 seconds.
The instrument's power
supply voltage is lower
than 10V.
The current measured by
the sensor exceeds the
alarm value set.
50
English
CORRECTIVE ACTION
Check the sensor electric
connections.
Check if sensor operates
properly. If not, replace it.
Check the position of
sensor and magnet on
gipsy and their distance
(3 mm).
Check the operation of
electric installation or
anchor windlass.
Verify the battery charge
or operation of the
electrics system.
Verify the operation of the
electric system. Reset the
alarm by pressing any
key.