Safety Switches TZ...
Correct use
Safety switches series TZ are interlocking devices
with guard locking solenoid (type 2). The actuator
has a low coding level. In combination with a movable
guard and the machine control, this safety compo-
nent prevents the guard from being opened while
a dangerous machine function is being performed.
This means:
Starting commands that cause a dangerous ma-
f
chine function must become active only when the
guard is closed and locked.
The guard locking must not be released until the
f
dangerous machine function has ended.
In applications for the protection of persons, the
f
position of the guard locking must be monitored by
evaluating the contact for the solenoid monitoring
(ÜK) in the safety circuit.
Closing and locking a guard must not cause auto-
f
matic starting of a dangerous machine function.
A separate start command must be issued. For
exceptions, refer to EN  ISO  12100 or relevant
C-standards.
Devices from this series are also suitable for process
protection.
Before the device is used, a risk assessment must
be performed on the machine, e.g. in accordance
with the following standards:
EN ISO 13849-1
f
EN ISO 12100
f
IEC 62061
f
Correct use includes observing the relevant require-
ments for installation and operation, particularly
based on the following standards:
EN ISO 13849-1
f
EN ISO 14119
f
EN 60204-1
f
Important!
The user is responsible for the proper integration
f
of the device into a safe overall system. For this
purpose, the overall system must be validated,
e.g. in accordance with EN ISO 13849-2.
If the simplified method according to section 6.3
f
of EN ISO 13849-1:2015 is used for determining
the Performance Level (PL), the PL might be re-
duced if several devices are connected in series.
Logical series connection of safe contacts is
f
possible up to PL  d in certain circumstances.
More information about this is available in
ISO TR 24119.
If a product data sheet is included with the prod-
f
uct, the information on the data sheet applies
in case of discrepancies with the operating
instructions.
Safety precautions
WARNING
Danger to life due to improper installation or due
to bypassing (tampering). Safety components
perform a personnel protection function.
Safety components must not be bypassed,
f
turned away, removed or otherwise rendered
ineffective. On this topic pay attention in partic-
ular to the measures for reducing the possibility
of bypassing according to EN ISO 14119:2013,
section 7.
The switching operation must be triggered only
f
by actuators designated for this purpose.
Prevent bypassing by means of replacement
f
actuators. For this purpose, restrict access to
actuators and to keys for releases, for example.
Mounting, electrical connection and setup only
f
by authorized personnel possessing special
knowledge about handling safety components.
CAUTION
Danger due to high housing temperature.
Protect switch against touching by personnel or
f
contact with flammable material.
Function
The safety switch permits the locking of movable
guards.
The switch contains a rotating switching disk and a
locking arm that block/release the guard locking pin.
The guard locking pin is moved on the insertion/
removal of the actuator and on the activation/
release of the guard locking. During this process
the switching contacts are actuated.
If the guard locking pin is blocked (guard locking
active), the actuator cannot be pulled out of the
switch head. For design reasons, guard locking
can be activated only when the guard is closed
(prevention of inadvertent locking position (faulty
closure protection)).
Position monitoring of the guard and monitoring
of interlocking are performed via two separate
switching elements.
GN
SK
ÜK
1 2 3 4 5 6
Fig. 1: Function of safety switch TZ
The safety switch is designed so that fault ex-
clusions for internal faults in accordance with
EN ISO 13849-2:2012, Table A4, can be assumed.
Guard lock monitoring
All versions feature at least one safe contact for
monitoring guard locking. The contacts
opened when guard locking is released.
Door monitoring contact
All versions additionally feature at least one door
monitoring contact. Depending on the switching
element, the door monitoring contacts can be
either positively driven (contacts
tively driven.
The door monitoring contacts are actuated when
the guard is opened.
Version TZ1
(guard locking actuated by spring force and released
by power-ON)
Activating guard locking: close guard; no voltage
f
at the solenoid
Releasing guard locking: apply voltage to the
f
solenoid
The spring-operated guard locking functions in ac-
cordance with the closed-circuit current principle. If
the voltage is interrupted at the solenoid, the guard
locking remains active and the guard cannot be
opened directly.
If the guard is open when the power supply is
interrupted and is then closed, guard locking is
activated. This can lead to persons being locked
in unintentionally.
6
Version TZ2
(guard locking actuated by power-ON and released
by spring force)
Important!
Use as guard locking for personnel protection is
possible only in special cases, after strict assess-
ment of the accident risk (see EN ISO 14119:2013,
section 5.7.1)!
Activating guard locking: apply voltage to the
f
solenoid
Releasing guard locking: disconnect voltage from
f
the solenoid
The magnetically actuated guard locking operates in
accordance with the open-circuit current principle. If
the voltage at the solenoid is interrupted, the guard
locking is released and the guard can be opened
directly!
Switching states
The detailed switching states for your switch can
be found in Fig. 5. All available switching elements
are described there.
Guard open
The safety contacts
Guard closed and not locked
The safety contacts
contacts
are open.
Guard closed and locked
The safety contacts
RD
Selection of the actuator
NOTICE
Damage to the device due to unsuitable actuator.
Make sure to select the correct actuator.
Additionally pay attention to the door radius and the
mounting options (see Fig. 6).
Manual release
Some situations require the guard locking to be
released manually (e.g. malfunctions or an emer-
gency). A function test should be performed after
are
release.
More information on this topic can be found in the
standard EN ISO 14119:2013, section 5.7.5.1. The
device can feature the following release functions:
Auxiliary release
In the event of malfunctions, the guard locking can
) or not posi-
be released with the auxiliary release irrespective
of the state of the solenoid.
The contacts
release is actuated. A stop command must be
generated with these contacts.
Actuating auxiliary release
1. Remove key from sealing wire.
2. Remove locking screw.
3. Release by turning the key.
Guard locking is released.
¨
Important!
The actuator must not be under tensile stress
f
during manual release.
To prevent tampering, the auxiliary release must
f
be sealed (with sealing lacquer, for example)
before the switch is set up.
After use, reset the auxiliary release and screw
f
in the locking screw and restore sealing using
a new seal.
and
are open.
are closed. The safety
and
are closed.
are opened when the auxiliary