Changeable Security-Relevant Settings; Transport; Disposal - Dräger Polytron 6100 EC WL Instrucciones De Uso

Ocultar thumbs Ver también para Polytron 6100 EC WL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 80
3. Keep the magnetic pen on the marking for 5 to 10 seconds (LED stops
flashing) and then take it off.
✓ The gas detector restarts and is reset.
13.3

Changeable security-relevant settings

PolySoft
Factory setting
SIL status
off
000000
®
Bluetooth
pairing PIN
Sample gas
sensor-specific
Sample gas module
sensor-specific
Measuring range
sensor-specific
Upper capture value limit
sensor-specific
Lower capture value limit
sensor-specific
Test gas
sensor-specific
Test gas unit
sensor-specific
Test gas concentration
sensor-specific
Calibration interval
sensor-specific
A1 alarm
sensor-specific
A2 alarm
sensor-specific
Capture value
sensor-specific
Sample gas LEL factor
sensor-specific
PROFIsafe Watchdog Timeout 60,000
PROFIsafe Address F-Host
1
PROFIsafe Address F-Device
1
PROFIsafe Data Format
float
Instructions for use
|
Dräger Polytron
®
6100 EC WL, Dräger Polytron
PolySoft
Factory setting
ISA 100 Provisioning
Over the Air
ISA 100 Tag Name
Serial number of the device
ISA 100 Network ID
0
14

Transport

The gas detector contains lithium batteries. During transport, especially when
transporting the gas detector by air, observe the relevant safety regulations and
the marking for lithium batteries.
15

Disposal

This product must not be disposed of as municipal waste. It is therefore
marked with the adjacent symbol. Dräger will take back this product for
free. For information please contact the national marketing organiza-
tions or Dräger.
Batteries must not be disposed of as household waste. They are there-
fore marked with the adjacent symbol. Dispose of batteries and
rechargeable batteries at battery collection points and in accordance
with current regulations.
Disposal of electrochemical sensors
WARNING
Danger of explosions and risk of chemical burns!
Sensor fluids may leak out and can cause acid burns.
► Do not dispose sensors in fire
► Do not open with force
®
Repeater ISA
|
en
Transport
51

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Polytron repeater isa

Tabla de contenido