Cable Connection - STAMOS S-DIGITRON 200P Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 102

CABLE CONNECTION

!
CAUTION
When this welding machine is used under the circumstance with water, be sure
to adopt waterproof measures in the cable connection position. (If water enters
the connection position, the insulation resistance may decrease or even the
short circuit may occur between connecting lines, thus causing failures.
Be sure to pay attention to the following when connecting cables:
The length and wire diameter (sectional area) should be selected properly;
otherwise, the welding performance will decrease due to the voltage drop on the
cable.
Therefore, when connecting the extended cable, please note the following:
The relation between the cable extension and sectional area.
Shorten the connection cable length as possible.
When the cable is extended for use, the curling of the cable will be adverse to
the welding performance.
Try to use single cable and not to lengthen it in the middle.
3-phase connection
The yellow-green wire is used as a PE protective
wire connector. The three phases (black, brown
and blue) can be freely connected to L1, L2 and L3
en (please have it done only by a qualified electri-
cian).
Attention!!!
Welding devices equipped with 400V must be connected by a technician.
2. NAMES AND FUNCTION OF VARIOUS PARTS
Power Switch (Breaker)
EN
EN
Waterproof measures
Rev. 25.04.2019
46
46
!
CAUTION
Under the circumstance that the electric generator is used, be sure to discon-
nect the power supply when starting the generator.
Connection and disconnection operation of the power switch
Power-on state when the power switch is at ON point.
Power-off state when the power switch is at OFF point.
Front Wiring Part
S-DIGITRON 200P
S-DIGITRON 250P
S-DIGITRON 300P
Rev. 25.04.2019
EN
EN
About Power Supply
1 Terminal to electrode holder/TIG
welding gun
Reliably connects with the electrode
holder/TIG welding gun
2 Aviation socket
Connects with the cable of the con-
trol switch of the welding gun
3 Water-passing fast plug
Reliably connects with the connec-
tor of the TIG welding gun
4 Terminal to parent metal
Reliably connects with the cable of
the parent metal.