Pic. 4
Position the power cables
in the suction unit
housing and along the
external surface of the
pump body.
ATTENTION!
7.
ELETRICAL CONNECTIONS
ATTENTION!
BEFORE PROCEEDING WITH ANY OPERATION INVOLVING THE ELECTRIC PUMP SWITCH
OFF THE POWER SUPPLY.
MAKE SURE THAT THE ELECTRIC PUMP IS ALWAYS CONNECTED TO THE GROUNDING
CIRCUIT.
8.
GENERAL RECOMMENDATIONS AND SAFETY
- It is not allowed to put the pump into operation if before it has not been checked by special personnel.
ATTENTION!
- Installation, maintenance procedures and further repairs must be operated by specialized personnel possessing
adequate qualifications and equipped with right tools.
- Careful reading the documentation supplied with the product and further documentation enclosed referred to
commercial equipment.
- It is forbidden to use the product following a fault or inefficiency even if partial.
- It is not allowed any modifications or changes to the product if not authorized by the manufacturer.
- Before proceeding with any electrical operation make sure that the floor is not wet.
- Handling the electric pump using lifting means and harness that are fit for the purpose.
12
Pic. 5
Proceed to
assembly of the
assembly of the
suction screen
with fixing bolts.
HANDLE WITH CARE AND CIRCUMSPECTION USING LIFTING MEANS THAT ARE FIT FOR THE
PURPOSE.
MAKE SURE ABOUT THE CORRECT ALIGNMENT AND THAT THE FIXING BOLTS ARE
TIGHTENED IN ORDER TO GUARANTEE THE ASSEMBLY BETWEEN THE ELECTRIC MOTOR
AND THE PUMP BODY IN THE RIGHT WAY.
Pic. 6
Pic. 7
Proceed to
Electric Submersible
pump assembled.
cable guard.
Make sure that the power cable of the electric pump has
been sized to suit its length and that the same electric
pump is equipped with sectioning device complete with
protections against the power surge and indirect contacts.
Consult the use and maintenance instructions of the
motor for info about the electrical equipment and about
the electrical power values.