9.
REPAIR AND MAINTENANCE
Malfunctions: Probable causes and cures
MALFUNCTIONS
THE PUMP DOES NOT DELIVER
WATER ANY MORE
INSUFFICIENT DELIVERY AND
PRESSURE
THE PUMP STOPS FREQUENTLY
THE MOTOR CONSUMES
TOO MUCH POWER
10.
MAINTENANCE
The electric pump does not need any special maintenance operation if used according to manufacturer's instructions. To prevent any
failure of the unit it is recommended to check the given pressure as well as the power consumption. As a matter of fact, less pressure
often means that the hydraulic parts of the pump are worn. Considering that bigger power consumption means that there are me-
chanical frictions inside the motor and inside the pump. The electric pump unit must be serviced and repaired by specialized personnel.
If required, it is allowed only the use of original spare parts.
PROBABLE CAUSE
The water bed level has gone down.
The pump cannot operate in dry conditions.
The suction screen is clogged.
The pump is covered with sand.
The suction screen is clogged.
The pump is covered with sand.
The three-phase electric pump is running
in the wrong way.
There are installation system losses.
The pump is worn.
Level drills intervention
(the pump capacity is too high).
Application with surge tank:
- The pressure sensor has not been
correctly calibrated.
- The surge tank capacity is insufficient.
The pump is covered with sand.
There are mechanical frictions.
ANY UNEXPECTED MODIFICATIONS AND PRODUCT TAMPERING ARE NOT ALLOWED.
WHEN NECESSARY ALWAYS CONTACT THE RETAILER ZONE.
Waiting for getting back to the 0 level and
lower the pump if possible.
Take the unit out and clean the suction
screen.
idem.
idem.
idem.
Check the connection.
Find out the losses and repair.
Take the pump out and it must
be checked by specialized personnel.
Reduce the use of water.
Set the calibration.
Replace the tank by a bigger one.
Take the pump out and repair it.
ATTENTION!
CURES
13
GB