Eu Declaration Of Conformity; Technical Data - EUCHNER SGA Serie Manual De Instrucciones

Interruptores de seguridad
Ocultar thumbs Ver también para SGA Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Safety Switch SGA...
Info: The year of manufacture can be seen in the
bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety regula-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
The following information applies to devices
with cable entry:
For use and application as per the requirements
of
a copper wire for the temperature range
60/75 °C must be used.
The following information applies to devices
with plug connector:
This device is intended to be used and applied with
a Class 2 power source in accordance with UL1310.
Connecting cables for safety switches installed at
the place of use must be separated from all moving
and permanently installed cables and un-insulated
active elements of other parts of the system that
operate at a voltage of over 150  V. A constant
clearance of 50.8 mm must be maintained. This
does not apply if the moving cables are equipped
with suitable insulation materials that possess an
identical or higher dielectric strength compared to
the other relevant parts of the system.
Version
Switching contacts
SGA.-528H...
1 NC + 1 NO contacts
SGA.-538H...
2 NC contacts
SGA.-2121H... 4 NC contacts
SGA.-2131H... 3 NC + 1 NO contacts
SGA.-3131H... 2 NC + 2 NO contacts
Fig. 2: Switching elements and switching functions

EU declaration of conformity

The declaration of conformity is part of the operating
instructions, and it is included as a separate sheet
with the device.
The original EU declaration of conformity can also
be found at: www.euchner.com
Service
If servicing is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Germany
Service telephone:
+49 711 7597-500
E-mail:
support@euchner.de
Internet:
www.euchner.com
Door closed
Door open
21
22
21
22
13
14
13
14
21
22
21
22
11
12
11
12
41
42
41
42
31
32
31
32
21
22
21
22
11
12
11
12
41
42
41
42
33
34
33
34
21
21
22
22
11
12
11
12
41
42
41
42
33
34
33
34
21
22
21
22
13
14
13
14

Technical data

Parameter
Housing material
Degree of protection
SGA1... (cable entry)
SGA2... (plug connector)/
SGA...L024...
Mechanical life
Ambient temperature
Degree of contamination
(external, acc. to EN 60947-1)
Installation orientation
Approach speed, max.
Extraction force
Retention force
Actuating force, max.
Actuation frequency
Switching principle
Contact material
Connection
SGA1...
SGA2...SR11
Conductor cross-section
(flexible/rigid)
SGA1...
Operating voltage for optional
LED indicator
Conditional short-circuit
current
Switching voltage, min.,
at 10 mA
Switching current, min., at 24 V 1 mA
Short circuit protection
(control circuit fuse) acc. to
IEC 60269-1
Convent. thermal current I
Utilization category acc. to EN 60947-5-1
SGA1...
SGA2...SR11
Rated insulation voltage
SGA1...
SGA2...SR11
Rated impulse withstand voltage
SGA1...
SGA2...SR11
Reliability values acc. to EN ISO 13849-1
B
10D
at DC-13 100 mA/24 V
Terminal assignment with plug
connector SR11
4.
7
3.
5
2.
3
1.
1
Ordinal numbers of switching elements
5
Value
Die-cast alloy
IP67
IP65
2 x 10
operating cycles
6
-20 ... +80 °C
3 (industrial)
Any
20 m/min
25 N
10 N
25 N
6,700/h
Slow-action switching contact
Silver alloy, gold flashed
Cable entry M20 x 1.5
Plug connector SR11, 11-pin+PE
0.34 ... 1.5 mm²
L024 24 V
100 A
12 V
4 A gG
4 A
th
AC-15 4 A 230 V /
DC-13 4 A 24 V
AC-15 4 A 50 V /
DC-13 4 A 24 V
U
= 250 V
i
U
= 50 V
i
U
= 2.5 kV
imp
U
= 1.5 kV
imp
3 x 10
6
Illustration of plug connector
SR11
View of safety switch connection side
PE
4.
8
8
11
3.
6
7
2.
4
6
1.
2
5
10
1
9
2
3
4

Publicidad

Tabla de contenido
loading

Tabla de contenido