Installation
4. Run the home power supply cable through the strain relief, into the terminal box.
A
C
D
5. Use UL listed wire connectors and connect the black wires (C) together.
6. Use UL listed wire connectors and connect the white wires (E) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect the ground wire to the green and yellow ground wire in the terminal box. Failure to do so can
result in death or electrical shock.
7.
Connect the green (or bare) ground wire from the home power supply to the yellow-green ground wire (F) in
the terminal box using UL listed wire connectors.
8. Tighten the strain relief screw.
9. Install the terminal box cover.
10. Reconnect the power.
To get the most efficient use from your new range hood, read the "Use and Care Manual". Keep your "Use and
Care", and "Installation" manuals close to the range hood for easy reference.

Install the Duct Covers

When using both upper and lower vent covers, push the lower cover down onto the hood and lift the upper cover
to the ceiling, and then install with two mounting screws.
NOTE
For vented installations, the upper vent cover may be reversed to hide slots.
B
F
E
A. Homepower Supply Cable
B. UL Listed or CSA Approved Strain Relief
C. Black Wires
D. UL Listed Wire Connectors
E. White Wires
F. Green (or Bare) and Yellow-Green Ground Wires