Assembly instructions
The device must be completely assembled before use!
While reading the text it is advisable to refer to the
„Overview of the Components" (Illustration B).
1. Insert the switch housing (12) into the stand (11).
Attach it on the bottom with the crosshead screw
(Illustration A).
2. Position the rear protection grid (7) in place in ac-
cordance with the recesses.
NOTE:
Please ensure that the carrying handle is facing
upwards.
3. Turn the attachment ring (6) for the rear protection
grid (7) slightly in a clockwise direction.
4. Attach the propeller. Note the position of the guide
pin on the motor shaft.
5. Tighten the attachment screw (4) for the propeller in
an anticlockwise direction.
6. Insert the front protective grille (1).
NOTE:
Ensure that the holes for the attachment screw in
the front and rear protective grille are aligned one
above the
other.
7. Tighten the protective grille with the attachment
screw (2) supplied.
8. Close the attachment hooks (3).
Position
The ideal position is a non-slip, fl at surface.

Wall Installation

You can also install the fan on the wall. Please remember
that there must be an electric socket close by.
Setting up the Fan (Illustration C)
1. Release the wing screw (14) on the joint.
2. Remove the stopper (13) by loosening the screw.
3. Turn the motor through 90°.
4. Turn the wing screw until it is hand-tight.
Attachment to the Wall (Illustration. D)
On the underside of the switch housing there are two
indentations. The distance between these indentations
is 46 mm.
• Drill two horizontal holes at this distance.
CAUTION:
Please ensure beforehand that you will not be
damaging any pipes or electric wires concealed in
the wall!
05-VL 5529 AEG.indd 24
05-VL 5529 AEG.indd 24
• Insert rawlplugs into the holes.
• Please use two screws of size 4 x 25 mm. Allow the
screws to protrude 10 – 12 mm out of the wall.
• Suspend the switch housing by the screws. Check
that it is fi rmly held in place.

Putting into Service

Electrical Connection
1. Before inserting the plug into the socket. Make sure
that the mains voltage to be used matches that of
the device. You can fi nd this information on the
nameplate.
2. Connect the device to a duly installed 230V/50Hz
protective contact socket.
Use
Basic Settings
Set the blower inclination angle before starting the
device.
• In order to do this, release the wing screw (14) and
move the fan to the desired position.
• Retighten the wing screw by hand.
NOTE:
The stopper prevents the fan from falling over.
Operation
Use the pushbutton switches on the front to select the
speed:
1 = slow, 2 = medium, 3 = fast.
Shift to „0" to switch off the device.
Blower Direction/Oscillation
You can choose from the two following options:
1.
The device must have been switched off before. The
setting knob must be pulled out.
Turn the device carefully with by hand by holding the
fan on the sides and turning it either to the left or to
the right until the limit
stop.
CAUTION: do not exceed this limit.
2. Select the automatic swinging direction by pressing
in the knob. The device swings automatically within
a range of 90°. This function is active only when the
fan is on. To deactivate the function pull out the set-
ting knob.