Important installation instructions
Hardware components
Accessories and cables
CAN converter
(optional)
Conergy SmartControl System
5.1
Included in delivery
| Operating manual
| Conergy SmartControl including analogue modems (incl.
serial no. of the complete Conergy SmartControl System)
| Power supply unit for supplying power to the Conergy
SmartControl
| ET sensor (irradiation and temperature sensor) with quick-
action catch
| Telephone cable with adapter for the country of installation
| Terminal strip with 6 screw terminals (Conergy
SmartControl accessory)
| Terminal strip with 4 screw terminals (power supply unit
accessory)
| 6 mounting rail bus connectors ME 22.5
| Terminal strip with 5 screw terminals (CAN cable
connection)
| 10 cm long, assembled cable with two sets of 5 screw
terminals for the connection of two CAN converters
| CAN converter
| Terminal strip with 3 screw terminals
The D-SUB terminal adapter and the 120
resistor required are included in the delivery of the inverter.
A CAN cable (3-pin) is not included in the delivery. CAN
cables must comply with the general specifications for CAN
cables. The CAN L and CAN H strands must be twisted
together. Where appropriate, the screened outer casing must
be weather resistant and suitable for laying underground. The
CAN cable supplied by Conergy fulfils these requirements.
Operating manual
5 Important installation instructions
Ω
terminating
31