6 Assembly and installation
38
12. Screw the cable with the screw plug (9), sealing ring (7)
and flat washer (8) to the housing (2).
13. Insert the connecting screw (1) into the housing and
tighten.
6.2
Installing the ET sensor
Before installation, consider on which module you will install
the ET sensor. Conergy recommends installing the ET sensor
on a module of your PV system which receives an average
amount of solar irradiation.
Centre of the module
Fig. 6-3: ET sensor on the module
(1) Irradiation sensor
(2) Module frame
(3a) Module (rear)
(4) Temperature sensor
(5) Connection box of the module
(6) Locking screw
CAUTION
Possible moisture damage to property.
Moisture in the housing may cause damage to the ET sensor.
| Do not connect the ET sensor when it is raining.
Operating manual
(1)
(6)
(5)
(4)
Conergy SmartControl System
(2)
(3a)