Install Mounting Bracket - Broan Elite E50000 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

All manuals and user guides at all-guides.com
INSTALL MOUNTING
BRACKET
1. Construct wood wall framing that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over installation
location.
b) the height of the framing will allow the
mounting bracket to be secured to the
framing within the dimensions shown.
2. After wall surface is finished, secure mount-
ing bracket to framing using dimensions
shown.
NOTE:
- On 8' ceilings, the hood distance above cook
top is :
minimum 24", maximum 27-1/2" (for
Ducted Configuration).
minimum 24", maximum 26-1/2" (for Non-
Ducted Configuration).
- On 9' ceilings, the hood distance above cook
top is :
minimum 26-1/2", maximum 30" (the air
vents on the upper flue will be exposed
after installation).
INSTALL FLUE MOUNTING
BRACKET
DUCTED AND NON-DUCTED
1. Assemble the flue mounting bracket,
adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket
directly over the range hood location.
3. Secure the bracket assembly to the ceiling
using (2) 4.8x38mm mounting screws
and drywall anchors. Make sure the
bracket is pushed into the corner, tight
against the wall and centered over the
hood.
FRAMING BEHIND DRYWALL
37-7/8"= bottom of hood 24" above
cooktop
43-7/8"= bottom of hood 30" above
cooktop
FLUE MOUNTING
BRACKET
(196.8mm)
- 7 -
3.9 x 6mm
FLAT HEAD
BRACKET SCREWS
7-3/4"
FIG. 4

Publicidad

Tabla de contenido
loading

Tabla de contenido