GAS - NOZZLE CALIBRATION
The boilers leave the factory calibrated and predisposed to operate with NATURAL GAS and LIQUID GAS.
These calibrations are effected without the connection of the compensating joint Pos. A (mod. MCS).
For the calibrations to put into effect, see the table related below:
Gas type
INOVA E 20MC W TOP INOVA E 20MCS W TOP
min.

NATURAL GAS

3,1
(G20-20 mbar)
LIQUID GAS B
6,6
(G30-28/30 mbar)
LIQUID GAS P
8,5
(G31-37 mbar)

BURNER PRESSURE CURVES - OUTPUT

kPa
mbar
G.N.
,2
12
11
1
10
9
8
MC
7
6
5
4
3
2
1
0
0
12,7
kW
9,3
13,9
11,6
16,2
kPa
mbar
P
34
32
,0
28
24
MC
,0
20
16
12
,0
8
4
0
0
12,7
kW
9,3
13,9
11,6
16,2
Minimum pressure (mbar)
• Slow ignition adjustment
3.4 mbars NATURAL GAS
6.6 mbars LIQUID GAS
All manuals and user guides at all-guides.com
Pressure on nozzles mbar
max.
min.
11,2
1,9
24,6
6,2
31,4
6,2
MCS
25,2
18,6
27,9
20,9
34,8
MCS
25,2
18,6
27,9
20,9
34,8
Delivery
max.
m
3
/h
10,7
2,53
25
0,73
32,8
0,96
kPa
mbar
2,6
26
24
22
2
20
18
16
14
12
1
10
8
6
4
2
0
0
12,7
kW
9,3
13,9
11,6
16,2
34
Burner
nozzles
L.C.V.
Ø mm.
kcal/h
1,2
8.550
0,75
29.330
0,75
22.360
B
25,2
18,6
27,9
20,9
34,8
A
Compensating joint
B
Connecting pipe
To effect the gas valve
calibration, proceed as
follows:
take the pipe (B) off
a)
the joint (A);
b)
effect calibration;
connect the pipe (B);
c)
again to the joint (A).