Descargar Imprimir esta página

Chauvet Professional NEXUS 2x2 Guía De Referencia Rápida página 4

Ocultar thumbs Ver también para NEXUS 2x2:

Publicidad

Idiomas disponibles

Idiomas disponibles

Nexus™ 2x2 QRG
Art-Net™
Connection
Kling-Net
Connection
Art-Net™/Kling-Net
Connection Diagram
Factory Reset
All manuals and user guides at all-guides.com
Art-Net™ is an Ethernet protocol that uses TCP/IP to transfer large
amounts of DMX512 data over a large network. Art-Net™ uses the
Neutrik® etherCON® connection. An Art-Net™ protocol document is
available from www.chauvetpro.com. Art-Net™ is Designed by and
Copyright Artistic Licence Holdings Ltd.
Kling-Net is a network protocol to allow auto configuration of display
devices over Ethernet. Kling-Net uses the Neutrik® etherCON®
connection. Refer to the ArKaos MediaMaster™ software manual for
detailed instructions on programming this product using this protocol.
Computer/Controller
(running Kling-Net
or Art-Net™ protocol)
This procedure allows you to reset the product to its original factory
settings.
1.
Unplug the Nexus™ 2x2 from power.
2.
Press and hold the <MENU/ESC> and <ENTER> buttons
simultaneously while plugging the Nexus™ 2x2 back into power.
3.
Release the <MENU/ESC> and <ENTER> buttons.
NOTE: Do not use WAN port!
Router
4
EN
To other
Kling-Net or
Art-Net™
Devices

Publicidad

loading