7.4.3.4 RTC Modo 3 - Year-Month-Day
This mode allows selecting a year, month and day to turn on the output, month and day to
turn off the output. It is necessary to enable the RTC block so that the output is turned on.
On the CLIC-02 display or in the programming tool, the RTC block Mode 3 is displayed
this way:
In this example the output will be turned on 02/17/2009 and turned off 11/11/2010. The
RTC block R03 will be activated only if the digital input I01 is active.
Ano/Mês/Dia
Year/Month/Day
Hora
Hour
Habilitação
Enabling
Output
Saída
Symbol
② ④⑤
⑥⑧
2009/02/17
2009/02/17
0:00
0:00
ON
OFF
- English -
Ladder Logic Programming
Description
RTC number: R01 ~ R1F
RTC Mode: 3
Current RTC value of CLIC-02
Year.Month.Day
Year to turn output on
Year to turn output off
Month to turn output on
Day to turn output on
Day hour to turn output off
Day minute to turn output off
③
①
⑨⑦
2010/11/11
2010/11/11
0:00
0:00
OFF
CLIC-02 | 93