9.6,
MANUALLY FILLING WITH W ATER.
The machine is equipped with a lever to manually fill the boiler with water in the
event of a fault of the filling electrovalve.
Remove the drip tray (1) complete with grille.
Operate the lever (2) to fill the boiler with water; when the maximum level has
been reached indicated by the indicator (3), release the lever (2).
9.7,
TURNING OFF.
W ARNING: Before turning off the machine, carry out the cleaning
operations described in the relative section.
Turn off the machine by turning the switch (1) to OFF "
the light (3) will go off.
Disconnect the differential switch located upstream of the machine and close
the water supply tap.