● OPERATING INSTRUCTIONS ●
W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
• This dries the inside of the unit.
• Moisture in the air conditioner contributes to favorable conditions for
growth of fungi, such as mold.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lter.
Page 5
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the earth is connected correctly.
4
Refer to the "PREPARATION BEFORE OPERATION",
and follow the instructions.
S
PECIFICATIONS
Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant fi lling capacity (R410A)
Indoor
IP code
Outdoor
LP ps
Permissible excessive
operating pressure
HP ps
Indoor (Super High/High/Med./Low)
Noise level
Outdoor
Guaranteed operating range
Indoor
32°C DB
Upper limit
23°C WB
Cooling
21°C DB
Lower limit
15°C WB
27°C DB
Upper limit
Heating
20°C DB
Lower limit
En-7
Page 4
Page 3
kW
kW
kg
kg
kg
MPa
MPa
dB(A)
dB(A)
Outdoor
46°C DB
15°C DB
24°C DB
18°C WB
-10°C DB
-11°C WB
DB: Dry Bulb
WB: Wet Bulb
I
NSTALLATION PLACE AND
ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke (such as cook-
ing areas and factories, in which the properties of plastic could be changed
and damaged).
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
Inverter-type
fl uorescent lamp
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
Keep a space to
prevent the pic-
ture distortion or
the noise.
1 m
or more
TV
1 m
or more
Cordless
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MSZ-HJ60VA
MSZ-HJ60VA
MUZ-HJ60VA
Cooling
Heating
~ /N, 230 V, 50 Hz
6.1
6.8
1.90
1.97
13
55
1.80
IP 20
IP 24
1.64
4.15
50/44/38/31
49/44/38/31
55
55
Note:
Rating condition
Cooling — Indoor:
27°C DB, 19°C WB
Outdoor: 35°C DB
Heating — Indoor:
20°C DB
Outdoor: 7°C DB, 6°C WB
The installation location of the outdoor unit should
be at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
wall, etc.
Well-
ventilated dry
place
100 mm or
more
500 mm or
more
3 m or
more
MSZ-HJ71VA
MSZ-HJ71VA
MUZ-HJ71VA
Cooling
Heating
7.1
8.1
2.33
2.44
50/44/38/33
49/44/38/33
55
55