Istruzioni Trioclean 02-03-2004 09:43 Pagina 14
pressing any button on the display). After 10 seconds the liquid has been pumped in the
bath. The alarm stops, but the spotlight keeps blinking (it is not possible anymore to stop
the cleaning cycle).
The water pump starts automatically and cleans the tubes during 3 minutes. After 3
minutes the pump stops and the bath can be emptied. Approximately 8 minutes after the
sensor feels no water in the bathtub, the spotlight then stops blinking and an acoustic
signal will be activated. If your system is equipped with the PLUS System during 2 minutes
clean water will be flushed through the tubes. After 5 minutes the blower will be activated
to blow air into the circuit for 1 minute at maximum speed to dry out all the residual water
in the air jets and air system pipes. The acoustic signal will then stop. A long buzzer sound
indicates the end of the cleaning cycle.
Led F functioning:
Off indicates the presence of disinfection liquid and means that the cleaning cycle is not
active. Blinking means that disinfection liquid is missing. On means that cleaning cycle is
being operated.
VISUAL PRESENTATION SYSTEM
14