EuroLite MINI-4 E Manual Del Usuario página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mini-4 B:
Attachment
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscilation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: On the baseplate, there are the holes for the installation.
Step 2: Hold the baseplate onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the baseplate in the desired position and tighten it.
Before taking into operation for the first time, the installation has to be approved by an expert!
Sound input
The sound signal is picked up via the integrated condensor microphone. This is why not extra connection to
the sound source is necessary.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Outputs
Output is via four IEC-output-sockets on the rearpanel.
Connect your loads via the output-socket. The maximum load per channel is 1150 W. Please note that the
maximum current of 5 A must never be exceeded.
DANGER TO LIFE!
International
L
N
12/25
MINI_4_V_1_2.DOC

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mini-4 mMini-4 b

Tabla de contenido