Franke Galaxy Slim 3 FX Instrucciones De Instalación E Utilización página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
GB
e- Check the connectors of the motor (Fig 9).
f- Test the lights and the fan motor.
g- Fit the metal grease filters and close the deflector.
IN THE RECIRCULATION MODE:
a- To carry out an inlet for recycling air in the kitchen (Fig.11).
b- Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape (Fig. 12).
c- Make the electrical connection of the motor as described in the section titled ELECTRICAL.
d- Place the canopy under the motor housing and fix it with the crews provided as illustrated in Fig. 10.
Attention: 2 persons are necessary to secure this operation.
e- Connect the electrical plug of the motor cord on the body hood (Fig.7).
f- Check the connectors of the motor (Fig 9).
g- Test the lights and the fan motor.
h- Fit the charcoal filter onto the inlets of the motor (Fig. 13).
i- Fit the metal grease filters and close the deflector.
• CLIPPAGE ON THE FALSE CEILING
2) Mark the centre of the cooking appliance onto the ceiling with a plumb line. Draw the horizontal axes
running parallel to the stove top onto the ceiling as illustrated Fig. 1.
3) To carry out the cutting of embedding in the suspended ceiling (Fig 2a).
4) To remove the lighting front panel (Fig. 15).
5) To unscrew the screws of the clips according to the thickness of the false ceiling (Fig. 16). When fixing
the cooker hood to a plasterboard ceiling ensure it is reinforced as illustrated in Fig. 17. For the false
ceiling in MDF of 18 mm, 4 holds of compensation (2 mm thickness) are provided with the hood.
6) Open the deflector ( Fig. 6 Rep. 12) by pushing / unlocking (Fig. 14).
7) To remove the metal filters.
IN THE EXTRACTION MODE:
a- Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing
down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connec-
tions with appropriate clamping rings or adhesive tape (Fig. 8).
b- Make the electrical connection of the motor as described in the section titled ELECTRICAL.
c- Place the canopy under the motor housing and fix it with the screws provided as illustrated in Fig. 10
or clip the hood on the false ceiling (Fig. 15), to tighten the screws (Fig. 16) and to fit back the lighing
front panel.
Attention: 2 persons are necessary to secure this operation..
d- Connect the electrical plug of the motor cord on the body hood (Fig.7).
e- Check the connectors of the motor (Fig 9).
f- Test the lights and the fan motor.
g- Fit the metal grease filters and close the deflector.
IN THE RECIRCULATION MODE:
a- To carry out an inlet for recycling air in the kitchen (Fig.11).
b- Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape (Fig. 12).
c- Make the electrical connection of the motor as described in the section titled ELECTRICAL.
d- Place the canopy under the motor housing and fix it with the screws provided as illustrated in Fig. 10
or clip the hood on the false ceiling (Fig. 15), to tighten the screws (Fig. 16) and to fit back the lighing
front panel.
Attention: 2 persons are necessary to secure this operation.
e- Connect the electrical plug of the motor cord on the body hood (Fig.7).
f- Check the connectors of the motor (Fig 9).
g- Test the lights and the fan motor.
h- Fit the charcoal filter onto the inlets of the motor (Fig. 13).
i- Fit the metal grease filters and close the deflector.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido