Storing
Before storing the unit for a longer periode of time, please follow the next steps :
· Drain all the water from the appliance.
· Afterwards turn on the unit in the "fan" mode for half a day. Make sure the unit is placed in
a heated room. This will dry the unit completely and previent the forming of mold.
· Turn off the unit, remove the plug from the socket and remove the batteries from the
remote control.
· Clean the filters and place them back in the unit.
· Store the unit in a dry, dark place.
POSSIBLE PROBLEMS AND THEIR SOLUTIONS
The appliance isn't working when pressing the on/off touch.
· The error code P1 is dispayed , drain the water from the airco.
· The room temperature is lower than the selected temperature. Adjust the selected
temperature.
The room is not cool enough.
· The windows and doors aren't closed. Make sure all windows and doors are closed.
· There are heat sources in the room. Remove all heat sources if possible.
· The air outlet hose is not connected or blocked. Attache the hose and check if there is no
blockage.
· The selected temperature is to high. Adjust the selected temperature.
· The air filter is dirty. Clean the air filter.
The appliance is making to much noise or is causing vibrations.
· The floor is nog level or flat. Place the appliance on the flat and level surface if possible.
· The air filter is dirty. Clean the air filter.
Your appliance makes a gurgling sound
· The sound is produced by the refrigerant in your appliance, this is normal.
ERROR CODES
Following error codes can be displayed on your airco :
E1 : the sensor for the room temperature is not working. Turn off the unit and remove the plug
from the socket. Wait for 10 sec and plug the unit back in. Turn on the unit. When the error
codes repeats, you need to contact the after sales service.
E2 : The sensor of the dehumidifier doesn't work. Turn off the unit and remove the plug from
the socket. Wait for 10 sec and plug the unit back in. Turn on the unit. When the error codes
58