Idiomas disponibles

Accuracy
Refer to "Specifications" for operating conditions and temperature
coefficient.
Accuracy is specified as follows: ± (a percentage of the reading + a fixed
amount) at 23 °C ± 5 °C (73.4 °F ± 9 °F), 0% to 80% relative humidity.
Amps
Measurement
Range
0.0 to 40.0 A
40.0 to 200.0 A
201 to 400 A
AC Voltage
Measurement
Range
200.0 V
600 V
DC Voltage
Measurement
Range
200.0 V
600 V
Resistance
Measurement
Range
200.0 Ω
2.000 kΩ
20.00 kΩ
200.0 kΩ
2.000 MΩ
20.00 MΩ
12
± (1.9% + 1 A)
± (1.9% + 0.5 A)
± (1.9% + 5 A)
Accuracy
± (1.5% + 0.5 V)
± (1.5% + 5 V)
± (1.0% + 0.2 V)
± (1.0% + 2 V)
± (1.2% + 0.5 Ω)
± (0.7% + 0.002 kΩ)
± (0.7% + 0.02 kΩ)
± (0.7% + 0.2 kΩ)
± (1.0% + 0.002 MΩ)
± (1.9% + 0.05 MΩ)
Accuracy
Frequency
Range
50 to 500 Hz
50 to 500 Hz
Accuracy
Accuracy
Frequency
Range
50 to 60 Hz
50 to 60 Hz
50 to 60 Hz
Input
Impedance
10 MΩ //
100 pF max
Input
Impedance
10 MΩ //
100 pF max