Changing cartridge
To change a cartidge safely, unplug the tool or turn the station off before following these guidelines:
1. Removing
Loosen the screw and remove the cartridge.
Use a flat pliers if still hot.
3. Aligning
Alignment
Align the tip of the cartridge.
Use a flat pliers for a correct tip alignment.
Do not over-tighten the cartridge.
Compatible cartridges
The CP station works with C120 cartridge range.
Find the model that best suits your soldering needs in www.jbctools.com
C120-004
1,5mm
ø0,7
6
2. Inserting
Important: Insert the cartridge as far as the
mark for a correct connection.
4. Fixing
Important: Tighten the screw again being
careful not to over-tighten. This is necessary
for the tool to function.
C120-005
5mm
Mark
C120-001
C120-009
C120-009
ø 0,2
C120-010
C120-010