G
B
POINT B - SETTINGS
DIP 1
MAINTENANCE CHECK (See Page 36)
DIP 2
PROGRAMMING (See Point C)
DIP 2-1
PROGRAMMING OF PEDESTRIAN OPENING (See Point D)
DIP 1-2
SAVE/DELETE RADIO CODES FOR COMPLETE OPENING (DIP 1 ON followed by DIP 2 ON)
(POINT E)
DIP 1-3
SAVE/DELETE RADIO CODES FOR PEDESTRIAN OPENING (DIP 1 ON followed by DIP 3 ON)
(POINT F)
DIP 1-2-3 SAVE/DELETE RADIO CODES FOR RELAY R-AUX COMMAND (point G)
DIP SWITCHES CONTROL
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON - activated).
DIP 8-9-10-11
IS NOT AVAILABLE
DIP 12
Activate the radio system SUN (ON) - SUN-PRO (OFF)
DIP 13
Contactors management (ON - activated)
NOTE: Even if enabled, DIPs 8-9-10-11 are excluded from their operation
DIP 14-15-16
IS NOT AVAILABLE
TORQUE TRIMMER - Electronic regulator for motor torque
IS NOT AVAILABLE
LOW SPEED TRIMMER - Electronic regulator for low speed on approach
IS NOT AVAILABLE
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator for TOTAL or PEDESTRIAN openings
by factory NOT ACTIVATED and LED DL11 OFF (trimmer fully rotated counterclockwise)
This trimmer makes it possible to adjust the pause time for total or pedestrian automatic
closing. Only with gate completely open (total) or partially open (pedestrian) and LED DL11 ON
(trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted from a minimum of 2 s up to a
maximum of 2 minutes.
The pause time (for gate open with PED. control) can be adjusted from a minimum of 2 s to a
maximum of 30 s.
Ex: With TCA trimmer setted halfway, you will have 1 minute pause after the total opening and
15 s of pause after the pedestrian opening prior to have the auto-close of the gate.
R-AUX - AUXILIARY RELAY CONTACT (NO)
By default this relay is set as courtesy light (max 700 W - 3 A - 230 Vac) to operate 3 minutes
at each command, with time renewed at each command.
You can activate the R-AUX contact by TRANSMITTER by performing the memorization
procedure described in point G.
ELECTRONIC BRAKE
IS NOT AVAILABLE
GRADUAL START
IS NOT AVAILABLE
LED WARNINGS
DL1
PROG programming activated
DL2
Gate opening
DL3
Gate closing
DL4
Opening limit switch LSO
DL5
Closing limit switch LSC
DL6
STOP command (NC)
DL7
PHOTO 1 contact (NC)
DL8
PHOTO 2 contact (NC)
DL9
EDGE 1 contact (NC)
DL10
EDGE 2 contact (NC)
DL11
TCA - automatic closure time enabled
DL12
Remotes programming enabled
DL13
L1 managed by APP
DL14
Encoder enabled
DL15
PROG and RADIO (on MOLEX connector) commands
B.I.O
Clock command (NO)
PED.
Pedestrian command (NO)
START Single impulse command (NO)
CLOSE CLOSE command (NO)
OPEN OPEN command (NO)
PROBE
NOT AVAILABLE
POINT C - TIMES PROGRAMMING
N.B .: During the programming the safety functions Coast, Photocells and Stop button are
N.B .: If the STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 inputs are not connected, make
N.B .: The start slow-down point is automatically determined in the time programming phase
N.B.: TO REPEAT THE PROGRAMMING REPOSITION THE GATE TO 20 CM FROM THE CLOSING LIMIT
1 - N.B .: POSITION THE GATE TO ABOUT 20 CM FROM THE CLOSING LIMIT SWITCH.
2 - Set DIP 2 to ON => LED DL1 will flash briefly.
3 - Press the PROG or START or OPEN button or the button of the remote control dedicated to
the total opening (if previously programmed). The gate will start a series of movements. DO
NOT PASS IN FRONT OF THE PHOTOCELLS WHILE THE GATE IS MOVING. The programming ends
when the gate is closed and the DL1 LED is OFF.
4 - AT THE END OF PROGRAMMING, RESET THE DIP 2 ON OFF.
D - PROGRAMMING OF PEDESTRIAN OPENING TIMES
With closed gate and closing limit switch engaged (mandatory).
1 - First set DIP 2 to ON (LED DL1 flashes quickly) and after DIP1 to ON (LED DL1 flashes slowly).
2 - Press the PED pedestrian button. or the remote control button dedicated to the pedestrian
opening (if previously programmed) => The gate opens.
3 - Press the pedestrian button PED. to stop the run (thus defining the opening of the gate).
4 - Press the pedestrian button to start closing.
5 - When the closing limit switch is reached, reset DIP1 and 2 to OFF.
During programming, the safety devices are active and their intervention stops the
programming (the LED from blinking remains lit steadily and the buzzer sounds for 10 s).
To repeat the programming position the DIP 1 and DIP 2 to OFF, close the gate and repeat the
procedure described above.
F - RADIO CODES PROGRAMMING PROCEDURE FOR TOTAL OPENING (1000 CODES
MAX) - with radio module ACG8069
ATTENTION: before storing the radio codes, use DIP 14 to select which transmitters to use:
DIP 14 OFF: SUN-PRO variable code transmitters can be memorized:
SUN-PRO 2CH 2-channel - red keys and white led cod. ACG6210
SUN-PRO 4CH 4-channel - red keys and white led cod. ACG6214
DIP 14 ON (by factory): You can store transmitters with fixed code SUN:
SUN 2CH 2-channel - blue keys and white led cod. ACG6052
SUN 4CH 4-channel - blue keys and white led cod. ACG6054
SUN CLONE 2CH 2-channel - blue keys and yellow led cod. ACG6056
SUN CLONE 4CH 4-channel - blue keys and yellow led cod. ACG6058
ATTENTION: it is not possible to memorize at the same time transmitters with fixed code and
(red)
(green)
Programming can be done only when the gate is stationary.
(red)
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 s.
(green)
2 - Press the TRANSMITTER button (usually channel A) within the allotted 10 s. If the remote
(red)
is memorized properly LED DL12 blinks green and a buzzer tone confirms the correct
(red)
memorization. The 10 s for programming the codes are automatically renewed, with LED
(red)
DL12 which flashes red, in order to store the next transmitter.
(red)
3 - To finish programming, wait 10 s, or press the PROG button briefly. LED DL12 stops flashing.
(red)
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
(red)
(red)
ALL RADIO CODES FOR TOTAL OPENING CANCELLATION PROCEDURE
(red/green)
Cancellations can only be performed when gate is stationary.
(blue)
1 - Set DIP 1 to ON and then DIP 2 to ON.
(red)
2 - LED DL12 flashes red for 10 s.
(green)
3 - Press and hold the PROG button for 5 s. Memory cancellation is indicated by two green
(green)
flashes of LED DL12 and 2 tones of the buzzer.
(green)
4 - LED DL12 flashes red again for 10 s and you can add new codes as shown above.
(green)
5 - Re-set DIP 1 to OFF and DIP 2 to OFF.
(green)
(green)
RADIO CODES MEMORY FULL INDICATOR (FOR TOTAL OPENING)
34
active and their performance level is PL "c" according to EN13849-1. their intervention
stops the programming (the led DL1 from flashing remains lit steadily).
jumpers between COM A+/STOP/PHOT 1/PHOT 2/EDGE 1/EDGE 2 before proceeding with
programming. N.B .: In this case the safety Edge, Photocells and Stop button will be
ignored.
and 50 ÷ 60 cm is activated before reaching the opening or closing limit switch.
SWITCH AND FOLLOW THE PROCEDURES BELOW.
transmitters with variable code.