PERSONAL PROTECTIVE EQUIPMENT TO WEAR WHILE OPERATING PNEUMATIC TOOL
Failure to observe the following warnings may result in physical injury and/or disease.
ALWAYS WEAR HEARING PROTECTION WHILE
OPERATING PNEUMATIC TOOL
ALWAYS WEAR EYE PROTECTION WHILE
OPERATING PNEUMATIC TOOL OR PERFORMING
MAINTENANCE JOBS
Additional personal protective equipment to wear according to the values found in the environmental hygiene/risk
analysis survey if the values exceed the limits under current regulations.
WEAR ANTI-VIBRATION GLOVES WHILE
OPERATING PNEUMATIC TOOL FOLLOWING A
SPECIALLY CONDUCTED SURVEY OF LEVEL OF
DAILY EXPOSURE OF HAND-ARM SYSTEM TO
VIBRATION
SPECIFICATION
Square
Model
Drive
mm
928 AC1 1/2
13
Average Air
Model
Consumption
l/min
928 AC1 1/2
147,2
* k = measurement uncertainty in dB
Air supply connection
For correct use of the pneumatic tool, always keep to a maximum pressure of 6.2 bars, as measured at the tool inlet. Feed the
pneumatic tool with clean, condensate-free air. Excessively high pressure or humidity in supply air results in shorter life for
the mechanical parts and may damage the tool.
EMERGENCY
GATE VALVE
Impact
Breakaway
Rate
Torque
bpm
Nm
1120
1490
Working
Weight
Pressure
bar
kg
6,2
2,8
** k = measurement uncertainty in m/s²
An air filter unit should be placed between air compressor and air lubricator
to promote clean air supply to the impact wrench Water, dirt, and scale can
damage the impact wrench .
ALWAYS WEAR PROTECTIVE GLOVES AGAINST
PHYSICAL AGENTS WHILE OPERATING
PNEUMATIC TOOL
ALWAYS WEAR SAFETY SHOES
WEAR PROTECTIVE MASK AGAINST PHYSICAL
AGENTS ACCORDING TO THE VALUES FOUND
IN THE ENVIRONMENTAL/INDUSTRIAL HYGIENE
SURVEY
Noise level (ISO 15744)
Pressure
Power
dB(A)
dB(A)
k*
k*
90
3
101
3
Dimensions
mm
190 x 70 x 193
The air tool must be lubricated before storing. Follow the
"Lubrication" instruction with exception of step 3.
Always use an air line lubricator with this tool.
Do not over-oil and do not use heavy grade oil as stalling and
low performance may result.
8
Vibrations
level
m/s
2
(ISO 28927-2)
k**
5,2
1,5