Power factor
Range
0.20 ÷ 1.00
Voltage and current harmonics (ACD-56HPQ only)
Harmonic order
1 ÷ 15
16 ÷ 25
Accuracy defined for: voltage ≥1.6V, current ≥2A
6.1.1. Safety standards
Comply with:
Insulation:
Pollution:
For inside use, max height: 2000m
Over voltage:
6.1.2. General data
Mechanical characteristics
Size:
Weight (including battery): about 280g batteries included
Jaws opening:
Max conductor size:
Power supply
Battery type:
Low battery indication:
Battery life:
Display
Characteristics:
Sample rate:
Conversion mode:
6.2.
ENVIRONMENTAL CONDITIONS
6.2.1. Climatic conditions
Reference temperature:
Operating temperature:
Operating humidity:
Storage temperature:
Storage humidity:
6.2.2. EMC
This apparatus was designed in accordance with EMC standards in force and its
compatibility has been tested in accordance EN61326 (1997) + A1 (1998) + A2 (2001).
This product conforms to the prescriptions of the European directive on low voltage
73/23/EEC (LVD) and to EMC directive 89/336/EEC, amended by 93/68/EEC.
6.3.
ACCESSORIES
6.3.1. Standard accessories
The accessories contained inside the packaging are the following:
• Instrument
• Test leads (MTL-90B)
• Carrying Case (SV-U)
Resolution
0.01
Resolution [V], [A]
EN 61010
Class 2, double reinforced insulation
Level 2
CAT III 600V between terminals and ground
205 (L) x 64 (W) x 39 (D) mm
30mm
30mm
2 batteries 1.5V LR03 AAA.
Symbol "
" is displayed when battery level is too low.
About 90 hours of continue measurement
4 dgt LCD with maximum reading 9999 units plus decimal
point and sign
64 samples in 20ms
TRMS
23° ± 5°C
5 ÷ 40 °C
<80% RH
-10 ÷ 60 °C
<80% RH
• Rubber holster (MTL-CAP)
• Alligator clips
• User's manual
EN - 29
ACD-51HP - ACD-56HPQ
Accuracy
± 3°
0.1
0.1
Minimum current
2A
Accuracy
±(10.0% rdg + 5 dgt)
±(15.0% rdg + 5 dgt)