TROUBLESHOOTING
PROBLEM
The burner will not
light with a match.
No gas flow or an
obstructed gas flow.
Low heat.
POSSIBLE CAUSE
1. Match not reaching burners
(when holding match with hand).
2. Gas supply shut off.
3. Poor connection between gas
hose plug fitting and sleeve
coupling.
4. Burner inlet blocked.
1. Gas supply shut off.
2. Poor connection between gas
hose plug fitting and sleeve
coupling.
3. Burner inlet blocked.
1. Insufficient gas pressure to the unit.
CORRECTIVE ACTION
1. Use match holder found in
cabinet door.
2. Check that the manual gas
supply shutoff valve is open.
3. Turn off the grill knobs, close the
gas supply shutoff valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
4. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
1. Check that the manual gas
supply shutoff valve is open.
2. Turn off the grill knobs, close the
gas supply shutoff valve and
check the connection between
the plug and sleeve coupling.
Disconnect and reconnect, if
necessary.
3. Clean the burner inlet (venturi)
and burner as described by the
Care and Maintenance section
in the manual.
1. Call a qualified service agency
to check the gas supply
pressure and correct the
pressure.