TO IgNITE THE fLAME follow the instructions below (see Cap. IGNITION) :
•
Bring the flue gas control to the LIgHTINg / HOB COOkINg UsE position (any butterfly valve placed on the flue gas exhaust pipe must
also be opened).
•
Open the primary and secondary air control.
•
After having started the fire with small pieces of wood and waited until it is well lit.
Bring the flue gas control to the OVEN position.
•
•
Close any butterfly valve placed on the flue gas exhaust pipe must also be opened.
The control regulation during the LIgHTINg phase is the following :
VERONA XXL
How to set the machine to BOIL WATER
• Turn the smoke adjuster to position cooker – OVEN COOkINg UsE pos. B
• Primary air completely open.
• secondary air completely open.
• Load wood as described in the manual (see chapter TECHNICAL DATA - Hourly wood consumption in kg/h).
• Wait for the oven temperature stable around 230 °C (+/-30°C).
How to set the machine to BAkE BIsCUITs
• Turn the smoke adjuster to the position cooker – OVEN COOkINg UsE pos. B
• Primary air completely open
• secondary air completely open.
• Wait for the oven to reach the temperature of 200 °C without loading further wood logs.
• Adjust the primary air control to the
• Place the tray with the biscuits into the second shelf from the bottom up for 20 minutes.
• Load wood by using logs having 1 Kg. weight.
• If necessary turn the tray halfway through cooking.
TECHNICAL DATA
Definition in accordance with
Nominal power in kW
Efficiency in %
Assorbimento elettrico in W
smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly wood consumption in kg / h
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
fire prevention safety distances
Heatable m
3
(30 kcal/h x m
Rated voltage (V)
Rated frequency (Hz)
Rated input power (W)
(*) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
26
1A - PRIMARY air
OPEN
Picture 6
position.
O)
2
(wood with 20% humidity)
)
3
2A - sECONDARY air
OPEN
Picture
6.
Picture
6.
ENgLIsH
B - sMOkEs control
LIGHTING / HOB COOKING
function
VERONA XXL
EN 12815
7
25
85,1
150
(*) 4 - 200 x 200 Ø 200
12 ( 1,2 mm H
O)
2
1,9
0,084 - 1044 mg/m
3
5,7
207
500 x 160
568 x 215 x 240
547 x 275 x 450
Movable - flat
850 - 910
800
600
175
Chapter FIRE sAFETY
200 (**)
230
50
25