Motor Specifications & Electrical Requirements; General Specifications; Double Insulated Tools - Skil 3310 Instrucciones De Funcionamiento Y Seguridad

Ocultar thumbs Ver también para 3310:
Tabla de contenido

Publicidad

SM 2610008289 02-10:3310 Table Saw 2/2/10 8:38 AM Page 6
Motor Specifications and Electrical Requirements

General Specifications

Voltage Rating . . . . . . . . . . . . . . . . . . .120 V, 60 Hz
Amperage Rating . . . . . . . . . . . . . . . . . . . . . . .15 A
No Load Speed . . . . . . . . . . . . . . . . . .N
Sawing capacity . . . . . . . .3" (7.62 cm) at 90 degrees
. . . . . . . . . . . . . . . . . .2 1/2" (6.35 cm) at 45 degrees
. . . . . . . . . . . . . . . . . . . . . . . . .1/2" (1.27 cm) with dado
Table size . . . . . . . . . . . . . . . . . . . . . . .18 7/8 x 26"

Double Insulated Tools

Double Insulation        is a design concept used in electric
power tools which eliminates the need for the three wire
grounded power cord and grounded power supply system. It is
a recognized and approved system by Underwriter's Lab-
oratories, CSA and Federal OSHA authorities.
IMPORTANT: Servicing of a tool with double insulation re-
quires care and knowledge of the system and should be
performed only by a qualified service technician.
WHEN SERVICING, USE ONLY IDENTICAL REPLACE-
MENT PARTS.
POLARIZED PLUGS. If your tool is equipped with a polarized
plug (one blade is wider than the other), this plug will fit in a
polarized outlet only one way. If the plug does not fit fully in
the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician to install the proper outlet. To reduce the
risk of electric shock, do not change the plug in any way.
W RNING
trocute.
5,000/min
W RNING
o
adequate size conductors should be used to prevent
excessive voltage drop, loss of power or overheating. The
table shows the correct size to use, depending on cord length
and nameplate amperage rating of tool. If in doubt, use the
next heavier gauge. Always use U.L. and CSA listed
extension cords.
RECOMMENDED SIZES OF EXTENSION CORDS
Tool's
Ampere
Rating
3-6
6-8
8-10
10-12
12-16
NOTE: The smaller the gauge number, the heavier the cord.
"SAVE THESE INSTRUCTIONS"
6.
Extension Cords
Replace damaged cords immediately. Use
of damaged cords can shock, burn or elec-
Always use proper extension cord. If an
extension cord is necessary, a cord with
120 VOLT ALTERNATING CURRENT TOOLS
Cord Size in A.W.G.
Cord Length in Feet
Cord Length in Meters
25
50 100 150
18
16
16
14
18
16
14
12
18
16
14
12
16
16
14
12
14
12
2
Wire Sizes in mm
15 30
60 120
.75 .75 1.5 2.5
.75 1.0 2.5 4.0
.75 1.0 2.5 4.0
1.0 2.5 4.0
— —

Publicidad

Tabla de contenido
loading