Bestron AAC7000 Manual Del Usuario página 47

Ocultar thumbs Ver también para AAC7000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
4. If the water collection tray is empty, put the lid and plug back in the drain hole, and make sure it is
properly closed.
Continuous drainage
If you often use the device to dehumidify the air, you can also use the continuous drainage. Attention:
continuous drainage only works in the "dehum"-mode.
1. Turn off the device and pull the plug from the
socket.
2. Unscrew the lid and plug from the continuous
drain hole (figure 1 No. 9), see figure 7)
3. Connect a drainage hose (not included) to the
continuous drain hole, and make sure the end of
the hose is placed in a bucket, or other kind of
collection tray.
4. Use the device as prescribed in this manual.
CLEANING AND MAINTENANCE - Cleaning the filter
For an optimal result, you have to clean the EVA-filter every two weeks, and replace at least 1x per year, or
more often if the filter is visibly full. Also clean the filter before you store it for longer periods of time, or when
you use it again after a long time.
1. Turn off the device and pull the plug from the
socket.
2. Use a cross-head screwdriver to remove the
filter from the back of the device (the middle
screw, see figure 8).
3. Rinse the filter with lukewarm water, or have it
soak in soapy water.
4. Let the filter dry properly.
5. Put the cleaned (or new) filter back in the device
and fixate it.
ATTENTION:
If the filter has not dried properly, water can
enter the device. This could cause (electrical)
damage.
47
EN
7
8

Publicidad

Tabla de contenido
loading

Tabla de contenido