Installation
4.5

Installation recess

The refrigerator must be installed draught-
proof in a recess (also refer to Section "4.1.4").
The measurements of the recess are stated in
the table below. Step (1) (Fig. 26) is only requi-
red for cabinets with a step. The floor of the
recess must be level, allowing the appliance to
be pushed easily into its correct position. The
floor must be substantial enough to bear the
weight of the appliance.

4.5.1 Installation in the recess

Push the appliance far enough into the recess
until the front edge of the refrigerator casing is
aligned with the front of the recess. Allow a
gap of 15-20 mm between the back wall of
the recess and the refrigeration unit.
Ensure that the refrigerator is installed
level in the recess.
min
15-20mm
1
T
ST
Model
RMS 8400
RMS 8401
RMS 8405
RMS 8460
RMS 8461
RMS 8465
RMS 8500
RMS 8501
RMS 8505
RMS 8550
RMS 8551
RMS 8555
RMSL 8550
RMSL 8551
RMSL 8555
H
ST
Fig. 26
16
Height H ST
Depth T ST
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm
235 mm
220 mm

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido