Supplier's model identifi er
Model
Certifi cate CE
Nominal capacity
Real capacity
Nominal pressure
Nominal heat rating
Useful rating
Heating time for DHW t 45°C
Heat loss at 65° Celsius (EN12867:2006)
Hot water fl ow rate
supply at 30K
supply at 40K
Erp DHW
Declared Load profi le
Water heating effi ciency ηwh
Water Heating effi ciency class
Daily electricity consumption Q
Daily fuel consumption Q
Sound power level LWA L
Emissions of nitrogen oxides
Annual electricity consumption AEC
Annual fuel consumption AFC
Mixed water at 40°C V40
Set-point temperature "out of the box"
Thermostat temperature settings
Gas supply pressure
G20 Methane
G30 Butane LPG
G31 Propane LPG
gas consumption
G20 Methane
G30 Butane LPG
G31 Propane LPG
Combustion gas values
Draught
Flue gas fl ow rate
Flue gas temperature
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.
TECHNICAL DATA
elec
fuel
WA
SGA X... - AG LNX... - TES X...
51CT4893
I
I
bar
kW
kW
min.
kW h/24h
I/h
l/h
%
kWh
kWh
dB
[mg/kWh]
kWh/annum
GJ/annum
l
°C
mbar
mbar
mbar
3
m
/h
kg/h
kg/h
mbar
g/sec
°C
GB
300
275
275
8
16
14
62
2,86
401
301
XXL
63
B
--
38,89
59
31
--
30,7
396
50
4
20
28 ÷ 30
37
1,69
1,262
1,243
0,015
16
137
37