EN
Y axis fine
Y-axis tuning, 16-bit
14
0-255
tuning
adjustment
15
X/Y speed
0-255
From slow to fast
0-255
No function
16
Reset
251-255
Head reset, 3S effects
24 channel mode
DMX
Channel
Function
value
1
Pan
0-255
540°
2
Tilt
0-255
270°
3
Zoom
0-255
10-60°
4
Dimming
0-255
0-100 Linear focusing
5
Red 1
0-255
Red 0-100%
6
Green 1
0-255
Green 0-100%
7
Blue 1
0-255
Blue 0-100%
8
White 1
0-255
White 0-100%
9
Red 2
0-255
Red 0-100%
10
Green 2
0-255
Green 0-100%
11
Blue 2
0-255
Blue 0-100%
12
White 2
0-255
White 0-100%
13
Red 3
0-255
Red 0-100%
14
Green 3
0-255
Green 0-100%
15
Blue 3
0-255
Blue 0-100%
16
White 3
0-255
White 0-100%
0-9
No function
17
Strobe
Strobe: flash speed from
10-255
slow to fast (1-25/s)
0-9
No function
10-19
R
20-29
G
30-39
B
40-49
W
50-59
RG
Color
60-69
GB
18
effect
70-79
RB
display
80-89
RW
90-99
GW
100-109
BW
110-119
RGB
120-127
RGBE
128-147
Colour change - effect 1
12
148-167
Colour change - effect 2
168-187
Colour change - effect 3
Color
18
effect
188-207
Colour change - effect 4
display
208-227
Colour change - effect 5
228-255
Colour change - effect 6
Color
change
19
0-255
From slow to fast
effect
speed
0-49
No function
X/Y Macro
X/Y Self-running (speed
20
50-180
function
from fast to slow)
181-255
X/Y Voice activation
X axis fine
X-axis tuning, 16-bit
21
0-255
tuning
adjustment
Y axis fine
Y-axis tuning, 16-bit
22
0-255
tuning
adjustment
23
X/Y speed
0-255
From slow to fast
0-255
No function
24
Reset
251-255
Head reset, 3S effects
2)
Signal connection diagram
SIGNAL
IN
OUT
OUT
OUT
IN
IN
IN
SIGNAL END
3)
Power connection diagram (max 4 connections)
AC100-240V
OUTPUT INPUT
OUTPUT INPUT
OUTPUT INPUT
POWER INPUT
3.3.2. MODEL CON.LMH-7/10/RGBW
1)
Programming
Menu
d001
001-512
Controller check
FASt
Fast, self-running
MStS
Voice mode
MAFA
MStc
Stand-alone mode
SIAu
Set Slave
MASL-SLOU
Slow mode
Pan
X motor forward
Pan
rPAn
Y motor forward
TiL
Y motor shift
TiL
rTiL
X motor shift
diS
Ahead view
diS
rdiS
Reverse exposure
14CH
14 channel mode
14CH
9CH
9 channel mode
PA54
X engine, 540 ° rotation
PA54
PA36
X engine, 360 ° rotation
PA18
X engine, 180 ° rotation
Ti27
Y engine, 180 ° rotation
Ti24
Ti18
Y engine, 90 ° rotation
Ti09
Y engine, 45 ° rotation
REST
REST
Return to saved status
LOAD
LOAD
Original factory settings
14 channel mode
1
0-255
Horizontal
2
0-255
Horizontal blackout
3
0-255
Vertical
4
0-255
Vertical blackout
5
0-255
Speed
0-7
No function
8-134
Blackout
6
135-239
Strobe (from slow to fast)
240-255
Medallion
7
0-255
Red blackout
8
0-255
Green blackout
9
0-255
Blue blackout
10
0-255
White blackout
0-7
No function
11
8-231
Colour combination 1
232-255
Flicking colours
12
0-255
Colour speed
0-127
Auto
13
128-255
Sound 1
14
150-200
Reset
9 channel mode
1
0-255
Horizontal
2
0-255
Vertical
Blackout and strobe
0-7
No function
8-134
3
Blackout
135-239
Strobe (from slow to fast)
240-255
Medallion
4
0-255
Red blackout
EN
5
0-255
Green blackout
6
0-255
Blue blackout
7
0-255
White blackout
8
0-255
Motor speed
9
150-200
Reset
3.4. CLEANING AND MAINTENANCE
a)
Always unplug the device before cleaning it.
b)
Use only non-corrosive cleaners to clean the surface.
c)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
d)
Do not spray the device with a water jet or submerge
it in water.
e)
Do not allow water to get inside the device through
vents in the housing of the device.
f)
Clean the vents with a brush and compressed air.
g)
The device must be regularly inspected to check its
technical efficiency and spot any damage.
h)
Use a soft cloth for cleaning.
i)
Do not clean the device with an acidic substance,
agents of medical purposes, thinners, fuel, oils or
other chemical substances because it may damage
the device.
DISPOSING OF USED DEVICES
Do not dispose of this device in municipal waste systems.
Hand it over to an electric and electrical device recycling
and collection point. Check the symbol on the product,
instruction manual and packaging. The plastics used to
construct the device can be recycled in accordance with
their markings. By choosing to recycle you are making
a significant contribution to the protection of our
environment. Contact local authorities for information on
your local recycling facility.
13