Technical data

Voltage supply
Continuous current consumption < 150 mA
Peak current consumption
Number of relays
Contact rating of relays
Switching power
Data retention on power cut
Protective system
Operating temperature range
Relative humidity
(non-condensing)
Cable length
Recommended cable
Max. conductor cross section
(screw terminals)
Mounting of control unit
Wall terminal R2 Dialock - status: 12.2016 - 732.29.132
34
Mounting and Operating Instructions
DC voltage
AC voltage
300 mA
4
DC voltage
AC voltage
Peak current
Continuous current max. 1 A
max. 30 W / max.60 VA
7 days
Reader unit IP 65
Control unit IP 20
Reader unit
Control unit
0 - 95 %
(reader - control unit) max. 50 m
J-Y(St)Y 2 x 2 x 0.8
Reader unit
Control unit
Top-hat rail to DIN EN 50 022
9 - 40 V
8 - 36 V
max. 60 V
max. 125 V
max. 2 A (1s max.)
-20 °C ... + 70 °C
-20 °C ... + 70 °C
2
1.0 mm
2
2.5 mm