Technical Data - ATH-Heinl Frame Lift 35FZ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 196
1.4

Technical Data

Model
Load capacity
Lift time
Lower time
Electric system
Control voltage
Motor
Rotation speed
Upstream fuse
Connection cable
Protection type
Working pressure ²
Recommended
hydraulic oil
Oil quantity
Floor anchor
Scissors
Floor anchor
Control box
Floor anchor
Bridging track
sections
Permissible sound
level
Weight
²
The factory set working pressure is adjusted to the maximum rated power. The pressure relief valve
must not be manipulated. Changing the settings can lead to serious damage.
If the stated rated load can not be lifted, please contact our service team.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2021-03
ATH Frame Lift 30FZ
3/400V/50Hz
Min. 5 x 1.5 mm²
260 -280 bar
Summer: H-LPD 46 (e.g.: OEST H-LPD 32 DD L)
Winter: H-LPD 32
≤ 75 dB (A)/lm
Manufacturer ATH-Heinl GmbH & CO.KG
- 8 -
3,500 kg
Ca. 52 s
Ca. 52 s
DC24V
2.6 kW
1,375 rpm
3 C 16 A
IP 54
12l
8 units
4 units
16 units
1090 kg

Publicidad

Tabla de contenido
loading

Tabla de contenido