Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
5.2.3
Heating system
The product is heated by the passage of steam through the double jacket. The lower
portion of the vessel has a 4-20mA temperature sensor that allows regulating the
temperature acting on the pneumatic steam inlet valve.
TEMPERATURE SENSOR
Manufacturer:
Type:
Sensor model:
Transmitter model:
Measurement range
Rod material
Connection:
5.2.4
Safety elements
The tank has the following safety elements:
PRESSURE GAUGE
The tank is provided with a pressure gauge at the top of the double
chamber to continuously measure the pressure therein.
Manufacturer:
Model:
Range:
Connection:
Material:
VÁLVULA DE SEGURIDAD
The safety valve is in contact with the atmosphere inside the double
chamber. In case of overpressure exceeding the safety valve's nominal
pressure, the valve will open, thereby relieving the excess pressure.
Fabricante:
Modelo:
Material:
Tara:
Conexión:
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
WIKA
PT100; Class B
TR10-B
T19
0...+140°C
AISI 316L stainless steel
Clamp 1½"
WIKA
233.50.100
0 to 4bar
½" GAS thread
AISI 316L
BOPP & REUTHER
SIC 13
Acero Inoxidable
3 bar
½'' x 1
Client:
UNIPHARMA
Date:
11-2015
EN
ES
MDI VCR (v1.0)