Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
Datasheet
Temperature control Skid - TSK SW Model
PRINCIPALES CARACTERÍSTICAS
MAIN CHARACTERISTICS
Longitud Total
Total Length
Altura Total
Total Height
Ancho Total
Total Width
MATERIALES Y ACABADOS
MATERIALS AND FINISHES
Structure
Estructura /
Pipes
Conducciones /
Aislamiento conducciones /
CHILLED WATER
Presión Entrada Agua Skid
Water Inlet Pressure at skid
Caudal (agua de chiller 8ºC)
Flow (chilled water 46'4 ºF)
STEAM
Presión vapor Entrada skid
Steam Inlet Pressure at skid
3
Caudal
Flow
COMPRESSED AIR
Presión Máxima
Maximum Pressure
Recommended steam flow for heating using 2 sections of the dimple jacket.
3
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
Pipe insulation
Client:
UNIPHARMA
TSK SW09
1286 mm
50,63''
1682 mm
66,22''
520 mm
20,47''
AISI 304 L
AISI 304 L
Black Elastomeric Insulation
2 bar(g)
3 m
3
/h
3 bar(g)
120 kg/h (VCR)
50 kg/h (MET)
0,5 bar
Date:
11-2015
EN
ES
MDI VCR (v1.0)
30 of 153