Care and maintenance of your pH Perfect

1
> Remove the protective cover
carefully drawing it towards you.
Figure
1.
4
> Position the tablet holder on
"10:20" turning clockwise.
Figure
4.
34
All manuals and user guides at all-guides.com
5.1.

Changing the peristaltic pipe

2
> Position the tablet holder on
"10:20" turning clockwise.
Figure
2.
5
> Insert the left-hand connection
in its housing, then pass the tube
under the guide of the tablet holder.
Turn the tablet holder clockwise and
at the same time put the tube
into the pump head up to the
right-hand connection.
Figure
5.
3
> Fully release the left-hand
connection keeping it stretched
outwards, then turn the tablet
holder clockwise in order to free
the tube up to the right-hand
connection.
Figure
3.
6
> Replace the protective cover (place
the pin in the attachment hole).
Figure
6.