FaiLUre
The shutter does not move but I can hear
the relays click for 1 second.
The shutter stops while it is opening and
then moves the opposite way.
The shutter stops while it is closing and
then moves the opposite way.
The shutter opens a little after closing
completely.
The shutters stop during movement only
when operated by the centralised control.
Some shutters open and others close
when the centralised control is operated.
Module configuration code summary table
Code Action
Recall of the intermediate position
2
Centralised opening
3
Centralised closing
4
Saving the current position of the shutter as
5
the intermediate position
Delete intermediate position
6
CENTRALISATION
Two centralisation modes are possible:
1) radio using module code 5454816 or a remote control.
2) wired using module code 5454818
Two modes are also possible for radio centralisation according to the number of modules to be controlled and the distance bet-
ween the various modules:
• Direct mode: up to 4 modules per pushbutton
• Radio bus mode: unlimited number of modules
Refer to the transmitter instruction booklet or the "Radio Memo" or go to the www.yokis.com website for more information.
iMPortaNt - the modules may also be centralised using a driver wire. it may be useful to plan the use a dedicated
driver wire for centralisation in some peculiar installations, during module wiring.
WARRANTY: In addition to the warranty required by law, this product is guaranteed for 5 years from the date of manufacture. The material must be used
according to the instructions provided and for its intended use. Faults must not be caused by deterioration or accidents resulting from negligence, anomalous
use, or incorrect installation. In all cases, the warranty only includes replacement of faulty products. No compensation for loss or damages may be claimed.
DS1054-065A
CaUSe
- The motor wires may be
disconnected.
- The motor already has an
integrated torque limiter.
- The motor wires may be
inverted.
- Too much strain on the motor.
- The shutter slats are offset and
rub against the sliding guides.
- The lower limit switch has
moved and the motor is forcing
against the hinge.
- The mains power is
inadequate.
- The motor wires on some
modules are inverted.
number of
confirmation
Code Action
movements
-
12
Opening
14
Closing
16
2
17
3
19
20
21
23
24
25
26
27
- Check operation of the shutter by disconnecting the motor wires from the
MVR500EBRP and applying power directly to them.
- The MVR500EBRP module must self-configure after 3 or 4 up and down
button tests. If it does not, briefly press one of the two button 24 times.
- Check the connection of the motor wires. To do this, briefly press one of
the two buttons 3 times to open the shutter. If the shutter closes,
it means that the connection is reversed.
- Try increasing the motor torque by briefly pressing one of the two buttons
19 times.
- Try increasing the motor torque by briefly pressing one of the two buttons
19 times.
- Try increasing the motor torque by briefly pressing one of the two buttons
19 times.
- Avoid using excessively long wire extensions or wires with insufficient
cross-section area to power the construction site.
- Briefly press one of the two buttons on the device 3 times to open the
shutter. If the shutter closes, it means that the motor wires are reversed on
the terminal board (see above).
Contact Customer Care for electronic limit switch configuration
Defining of the lower electronic limit switch
Defining upper electronic limit switch
Delete lower and upper limit switch
Cancel inverted movement in case of overload (toggle)
Increase motor torque (toggle)
Invert up/down wire logic (toggle)
Block of installer configurations (12-27)
Authorise installer configurations (12-27)
Deactivation of shutter motor torque controls with stroke less than
40 seconds and limit switch detection deactivation.
Reset default setting of the module
Deactivation of the shutter motor torque controls with stroke
longer than 40 seconds.
Reset the module to default settings, except for motor reversal.
P10
SoLUtioN