gas specification
Gas type &
Model No.
pressure
G30 29mbar
EMH750CGB
G20 20mbar
electrical connection
■ This appliance must be earthed.
■ This appliance is designed to be connected to a
■ The wires in the mains lead are coloured in accordance with the following code ;
- Green/yellow = Earth
- Blue
= Neutral
- Brown
= Live
■ The wire which is coloured green and yellow must be
connected to the terminal which is marked with the
letter E or by the earth symbol.
Electrical
power
Triple-Crow burner
3.3kW(241g/h)
220
-240Vac
0.93
50/60Hz
1.28
Heat input and orifice size marked(mm)
Rapid burner
Semi-rapid
3.0kW(219g/h)
1.75kW(127g/h)
0.85
0.65
0.97
1. 30
22
0
~240V, 50/60Hz AC electricity supply.
22
Auxiliary- rapid
Semi-rapid
1.75kW(127g/h)
1.0kW(73g/h)
0.65
0.50
0.97
0.72
Total Heat input
10.8kW(787g/h)
NA
V.2