GB
Filling the pump
Fill up the house water dispenser every time
before you start using it. Avoid dry running
of the pump! Danger of overheating!
Never touch an overheated pump! There
is a danger of burns!
When switching on the pump, ensure
that the pump and suction hose are com-
pletely filled with water in order to prevent
the dry running of the pump. Dry running
damages the device.
•
Open the filling screw (
domestic water pump.
•
Fill with water to the fill point such that
water starts to run out of the filling
A
screw (
1) hole.
•
Retighten the filling screw (
Operational start-up
•
Check that the electrical con-
nection is 230V ~50Hz
•
Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 10 A). In-
sert the pump plug into the plug
socket and the pump is ready
for operation.
•
Make sure that moisture or wa-
ter never come in contact with
the mains connection.
There is a risk of electrocution.
Starting the unit
•
Connect the power cable (
automatic switch to the power supply.
•
Set the On/Off switch (
on the unit.
•
If water is demanded, the automatic
switch will activate automatically if the
42
All manuals and user guides at all-guides.com
A
1) on the
A
1).
A
7) of the
A
13) to turn
pressure falls in the pressure vessel
(
5) and switch the pump on. Once
A
the water stops flowing the vessel
pressure will increase and the auto-
matic switch will switch the pump off.
Maintenance Instructions
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in these
instructions. Use only original parts.
Pull out the power plug before every
maintenance operation. There is a
risk of electrocution or of injury from
moving parts.
General cleaning instructions
A reduction in pump feed output may
be indicative of a blockage. In case the
unit clogs up, remove the suction and
pressure hoses. Flush water through the
threaded hole on the pump in order to re-
move the foreign body.
Any measures above and beyond these,
particularly opening the equipment, are to be
carried out by an electrician. In the case of
repairs, always contact our service centre.
Storage
•
Keep the equipment clean, dry and out
of the reach of children.
•
To keep the pump when not in use,
open the draining screw (
carefully drain the pump.
A
8) and