Maintenance; Maintenance Schedule; Maintenance Reminders; Maintenance Replacement Parts - Westinghouse WGen5300sc Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE

MAINTENANCE
Accidental start-up. Disconnect the spark plug boot from
the spark plug when performing maintenance on the
generator.

MAINTENANCE SCHEDULE

Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
Clean air filter
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Fuel valve maintenance
Inspect/adjust valve clearance
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Change oil every month when operating under heavy
1
load or in high temperatures.
Clean more often under dirty or dusty conditions.
2
Replace air filter if it cannot be adequately cleaned.
Recommend service to be performed by authorized
3
Westinghouse service dealer.

MAINTENANCE REMINDERS

Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
Maintenance Code Required Maintenance
P25
Change engine oil
P50
Change engine oil, clean air filter
P100
18 | Westinghouse Outdoor Power Equipment, LLC
1
2
3
• Inspect/clean spark arrestor
• Inspect/clean spark plug
• Fuel valve maintenance
• Inspect/adjust valve clearance

MAINTENANCE REPLACEMENT PARTS

Description
Air filter
Oil drain plug crush washer
Spark arrestor
Spark plug
12V 1.2 AH Lithium Ion battery 511085

AIR FILTER MAINTENANCE

The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Release the clips and remove the air filter cover.
3. Clean the air filter with compressed air. Replace if
damaged.
4. Make sure the air filter and rubber cap are correctly
installed. Install the air filter cover and secure it in place
with the cover clips.
Part Number
5941
94007
6790
97108 (F7TC)

Publicidad

Tabla de contenido
loading

Tabla de contenido