Troubleshooting Guide - The Fountainhead Group 190679 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
For assistance with your product, visit our website at
PROBLEM
The sprayer does not turn
ON (no audible hum of
the pump).
The sprayer turns ON
(pump head hums) but it
will not spray.
The sprayer turns ON
but only sprays at low
pressure.
The pump does not fully
prime.
The hose leaks at the tank
connection.
16

TROUBLESHOOTING GUIDE

BE SURE TO FOLLOW SAFETY RULES AND INSTRUCTIONS
POSSIBLE CAUSE
Ensure the battery is correctly
installed.
Ensure the battery is charged.
The battery may be damaged or
may have overheated. Visually
inspect the battery for damage.
The hose is pressurized. The pump
turned OFF automatically.
There is no liquid in the tank.
The shut-off filter is clogged.
The nozzle is clogged.
The in-tank filter is clogged.
The pump is not primed.
The shut-off filter is clogged.
The nozzle is clogged.
The in-tank filter is clogged.
The pump is not primed.
The liquid level in the tank is low.
The pump was run dry (without
liquid) before the tank was refilled.
There is chemical residue or build-
up in the tank and/or pump due to
improper or inadequate cleaning.
The in-tank filter is improperly
installed, missing, or damaged,
allowing debris to enter the pump.
The hose is cracked, swollen, or
faulty.
The connection is damaged.
www.thefountainheadgroup.com
Install the battery correctly. See Installing
the Battery.
Charge the battery. See Charging the
Battery.
Replace the battery if it is damaged or not
working. If the battery overheated, allow
the battery to cool.
Squeeze the shut-off lever to see if the
sprayer starts and the pump turns ON.
Add liquid to the tank. See Filling the
Sprayer.
Clean the shut-off filter. See Shut-off
Assembly Maintenance.
Clean the nozzle. See Nozzle Maintenance.
Clean the in-tank filter. See In-Tank Filter
Maintenance.
Allow at least 30 seconds for the pump
to prime.
Clean the shut-off filter. See
Shut-off Assembly Maintenance.
Clean the nozzle. See Nozzle Maintenance.
Clean the in-tank-filter. See In-Tank Filter
Maintenance.
Allow at least 30 seconds for the pump
to prime.
Add liquid to the tank. See Filling the
Sprayer.
Ensure the sprayer is OFF and squeeze the
shut-off lever until all pressure is relieved.
Clean the sprayer. See Cleaning. If
necessary, repeat with warm water and a
mild detergent mixture. Allow the mixture
to stay in the pump for up to 1 hour prior
to rinsing. Replace the pump if necessary.
Clean the sprayer. See Cleaning. If
necessary, repeat with warm water and a
mild detergent mixture. Allow the mixture
to stay in the pump for up to 1 hour prior
to rinsing. Replace the pump if necessary.
Replace the shut-off assembly.
Replace the shut-off assembly
or call 1-800-311-9903.
SOLUTION

Publicidad

Tabla de contenido
loading

Tabla de contenido