Module Errors
ID
Problem
9
The checksum of the station constants do not match
the station constants.
B
The watchdog telegram has not been received in 400
ms.
1E
The CAN send buffer has overflowed.
1F
The CAN receive buffer has overflowed.
23
The checksum of the calibration data is wrong.
53
The checksum of the local PLC on the gas control is
wrong.
60
The output to the valve on channel 1 is drawing too
much current.
61
The output to the valve on channel 2 is drawing too
much current.
62
The output to the valve on channel 3 is drawing too
much current.
63
The output to the valve on channel 4 is drawing too
much current.
64
The module's telegram counters do not match the inter-
face control's telegram counters.
65
The module has reset itself.
Maintenance/troubleshooting
This error will normally correct itself. If it continues, replace the module/board.
1. Check for all the dip switches on the IC board are toward the display.
2. Check for SW1 on the control board in the Plasma Console is set to "Closed"
3. Check for the CAN cable is properly connected to the module.
4. Check for coiling of the CAN cable near power leads.
Replace the gas control module.
Replace the gas control module.
1. Check for a short on the output of the channel.
2. Replace the valve.
1. Check for a short on the output of the channel.
2. Replace the valve.
1. Check for a short on the output of the channel.
2. Replace the valve.
1. Check for a short on the output of the channel.
2. Replace the valve.
1. Check for all the dip switches on the IC board are toward the display.
2. Check for SW1 on the control board in the Plasma Console is set to "Closed"
3. Check for the CAN cable is properly connected to the module.
4. Check for coiling of the CAN cable near power leads.
Solution