NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
○ If drain valve is clogged, release all air pressure by
pulling the safety valve. Remove and clean valve,
then reinstall.
WARNING
Remove the battery from the air compressor and
release all air from the tank before servicing.
Failure to depressurize tank before attempting to
remove valve may cause serious personal injury.
○ Close the drain valve by rotating it 1/4 turn clockwise.
Drain valve (closed)

END OF OPERATION/STORAGE

○ Turn the power switch to the OFF position.
○ Remove the battery.
○ Open the drain valve located at the lower part of the
tank (Fig. 15). Tank pressure should be below 10 psi
when draining the tank.
WARNING
Risk of bursting. When the tank gets corroded,
there is a risk of breakdown. Water will condense
in the tank. If not drained, water will corrode and
weaken the tank causing a risk of tank rupture.
Drain tank daily or after 4 hours of use. The drain
contains moisture in the air, abrasion particles,
rust, etc..
To drain tank open valve slowly and tilt
compressor to empty accumulated water. Keep
face and eyes away from drain cock.
○ Air hose should be disconnected from compressor
and hung open ends down to allow any moisture to
drain.
○ Compressor and hose should be stored in a cool, dry
place.
20
Drain valve (open)
Fig. 15

ABOUT REMAINING BATTERY INDICATOR

You can check the battery's remaining capacity by
pressing the remaining battery indicator switch to light the
indicator lamp. (Fig. 16, Table 5)
The indicator will shut off approximately 3 seconds after
the remaining battery indicator switch is pressed.
It is best to use the remaining battery indicator as a
guide since there are slight diff erences such as ambient
temperature and the condition of the battery.
When the battery's remaining capacity is low, the motor
may stop even if 1 light on the indicator lamp is lit up. This
is not the trouble but the result of protection function. If this
happens, recharge the battery as soon as possible.
Remaining battery
indicator lamp
Display panel
State of lamp
Lights ;
The battery remaining power is over
75%.
Lights ;
The battery remaining power is
50%–75%.
Lights ;
The battery remaining power is
25%–50%.
Lights ;
The battery remaining power is less
than 25%.
Blinks ;
The battery remaining power is
nearly empty. Recharge the battery
soonest possible
Remaining battery
indicator switch
Fig. 16
Table 5
Battery Remaining Power

Publicidad