Descargar Imprimir esta página

OBERON 1042-CCOAP3800 Guia De Instalacion página 2

Publicidad

Installation Guide /
Guía de instalación
for Oberon Model 1042-CCOAP3800
para Modelo Oberon
1042-CCOAP3800
1
Cut a 11.25" x 12.25" opening in the "hard lid" ceiling or wall (NOTE: special
cutting tools may be required).
Corte una abertura de 11.25 "x 12.25" en el techo o pared de "tapa du-
ra" (NOTA: herramientas de corte especiales pueden ser necesarias).
2
Place the backbox on a work surface. Remove one of the 1" knockouts on
the side of the enclosure and install the 1" trade size conduit connector (the
side on which the cable clamp is to be installed will be determined by the
location the enclosure is to be installed and direction from which conduit or
cable will be brought into the enclosure)
Attach the Speed Link to the center support bridge on the Oberon tile bridge
and then to a permanent structure within the ceiling.
Coloque la caja en una superficie de trabajo. Retire uno de los orificios
ciegos de 1 "en el costado del gabinete e instale el conector de conducto
del tamaño comercial de 1" (el lado en el que se instalará la abrazadera del
cable vendrá determinado por la ubicación del gabinete y la dirección desde
la cual conduit o cable serán traídos al recinto)
Conecte el enlace de velocidad al puente de soporte central en el puente de
losetas Oberon y luego a una estructura permanente dentro del techo.
"Oberon" and all other marks where denoted are trademarks of Oberon Inc.
"Oberon" y todas las demás marcas donde se denotan son marcas comerciales de Oberon Inc. © 1999-2017 Oberon Incorporated. Todos los derechos reserve.
All manuals and user guides at all-guides.com
3
NOTE: A surface mount box (or biscuit jack) and equipment cord can be
conveniently mounted inside the Model 1042. (Non-plenum rated cables
can be used inside a plenum rated enclosure). Use an adhesive backed
surface mount box. Consider bend radius of horizontal cable and equip-
ment cord when attaching the surface mount box.
Insert the Ethernet cable through the conduit connector previously installed
in the enclosure. Insert the box into the opening in the ceiling/wall and using
either a hand held screw driver or an electric screw driver set to the lowest
torque setting, rotate the screws located at the four corners. Rotating the
screws will cause the dogleg clip to rotate into position (#2 in Figure 3) and
travel along the length of the screw, tightening the clip against the drywall.
Caution, do not over tighten the screws as it may damage the flange of the
enclosure. See OSHPD approved drawing where applicable.
NOTA: Una caja de montaje en superficie (o conector para galletas) y el
cable del equipo pueden montarse convenientemente dentro del Modelo
1042. (Los cables que no se encuentran en el plenum pueden usarse
dentro de un gabinete con clasificación de plenum). Utilice una caja de
montaje de superficie con respaldo adhesivo. Considere el radio de
curvatura del cable horizontal y el cable del equipo cuando lo conecte a la
caja de montaje de la superficie.
Inserte el cable de Ethernet a través del conector de conducto previamente
instalado en el gabinete. Inserte la caja en la abertura del techo / pared y
con un destornillador de mano o un destornillador eléctrico con la
configuración de torque más baja, gire los tornillos ubicados en las cuatro
esquinas (N.º 1 en la Figura 3). Girar los tornillos hará que la pinza dogleg
gire en su posición (n. ° 2 en la Figura 3) y se desplazará a lo largo del
tornillo, apretando el clip contra el panel de yeso. Precaución, no apriete
demasiado los tornillos ya que pueden dañar la brida del gabinete. Ver el
dibujo aprobado por OSHPD donde corresponda.
©1999-2018 Oberon Incorporated. All rights reserved.
4
NOTE: A surface mount box (or biscuit jack) and equipment cord can be
conveniently on the back side of the Model 1040. Use an adhesive backed
surface mount box. Consider bend radius of horizontal cable and equip-
ment cord when attaching the surface mount box.
The torsion spring that is used to secure the trim assembly to the tile bridge
is shipped separately (to prevent damage) and must be installed prior to the
first use. To install torsion springs, first detach the mounting plate from the
trim face by removing the four thumb nut
NOTA: Una caja de montaje en superficie (o conector para galletas) y el
cable del equipo pueden estar convenientemente en la parte posterior del
Modelo 1040. Use una caja de montaje de superficie con respaldo
adhesivo. Considere el radio de curvatura del cable horizontal y el cable
del equipo cuando instale la caja de montaje en superficie.
El muelle de torsión que se usa para asegurar el conjunto de moldura al
puente de losetas se envía por separado (para evitar daños) y debe
instalarse antes del primer uso. Para instalar muelles de torsión, primero
separe la placa de montaje de la cara de ajuste quitando las cuatro tuercas
de mariposa
5
Install the two torsion springs by: A pinching the tips together, and B
inserting the tips into the rectangular openings on each end of the
mounting bracket .
Instale los dos muelles de torsión: A juntando las puntas, y B insertando las
puntas en las aberturas rectangulares en cada extremo del soporte de
montaje.
Mounting Solutions for WiFi Access Points
6
The Cisco 2800e, 3800e, and 3800i AP's should be aligned with the Oberon
mounting plate so that the flange on the bottom of the Oberon mounting
plate is opposite the Ethernet ports on the AP, the mounting plate that
comes with the Cisco Access point is only required for use with the Cisco
2700i. All other variations get attached directly to the Oberon mounting
plate Attach the Cisco access point to the Oberon mounting plate by insert-
ing the mounting feet on the bottom of the Cisco access point into the key-
hole slots and sliding the AP to lock into position, as shown.
Los Cisco 2800e, 3800e y 3800i AP deben alinearse con la placa de
montaje Oberon de modo que la brida en la parte inferior de la placa de
montaje de Oberon esté opuesta a los puertos Ethernet en el AP, la placa
de montaje que viene con el punto de acceso de Cisco es requerido para el
uso con Cisco 2700i. Todas las demás variaciones se conectan
directamente a la placa de montaje de Oberon. Fije el punto de acceso de
Cisco a la placa de montaje Oberon insertando las patas de montaje en la
parte inferior del punto de acceso de Cisco en las ranuras de la bocallave y
deslizando.
7
Reassemble the trim by attaching the trim piece which was previously
removed by inserting the studs into the slotted holes and installing the
thumb nuts.
Vuelva a ensamblar la moldura uniendo la moldura que se retiró
previamente insertando los pernos en los orificios ranurados e instalando
las tuercas de mariposa
EPN 3494 - Rev. #1 02/07/2018