TECHNICAL PARAMETERS
EN
1.
Nominal volume V, liters - see the appliance's rating
plate
2.
Nominal voltage - see the appliance's rating plate
3.
Nominal power consumption - see the appliance's
rating plate
4.
Nominal pressure - see the appliance's rating plate
This is not the water mains pressure. This is the pressure
that is announced for the appliance and refers to the
requirements of the safety standards.
5.
Water heater type - closed type accumulating water
heater, with thermal insulation
6.
Daily energy consumption – see Annex I
7.
Rated load profile - see Annex I
8.
Quantity of mixed water at 40°C V40 litres - see Annex I
9.
Maximum temperature of the thermostat - see
Annex I
10.
Default temperature settings - see Annex I
11.
Energy efficiency during water heating - see Annex I
III.
DESCRIPTION AND PRINCIPLE OF WORK
The appliance consists of a body, flange at the bottom
side /for water heaters intended for vertical mounting/
or at the sides /for water heaters intended for horizontal
mounting/, protective plastic panel safety-return valve.
1.
The body consists of a steel reservoir (water tank)
and housing (outer shell) with thermal insulation
placed in-between made of ecologically clean high
density polyurethane foam, and two pipes with thread
G ½ '' for cold water supply (marked by a blue ring) and
hot water outlet pipe (marked by a red ring).
The inner tank made of steel protected form corrosion by
a special glass-ceramics coating.
2.
The flange is outfitted with: electric heater and
thermostat. The water heaters with glass-ceramics
coating are outfitted with a magnesium protector.
The electric heater is used for heating the water in
the tank and is managed by the thermostat, which
automatically maintains the set temperature.
The thermostat has a built in overheating safety device,
which switches of power to the heater when the water
temperature reaches excessive values.
3.
The safety-return valve prevents the appliance's
complete emptying in the event the cold water supply
is interrupted. The valve protects the appliance from
pressure increases higher than the allowed value
during heating (! pressure increases upon an increase
of temperature), via release of excess pressure during
the drainage opening.
The safety-return valve cannot protect the appliance in the
event of water mains pressure in excess of the acceptable
pressure stated for the appliance.
IV.
MOUNTING AND SWITCHING ON
Attention! Improper installation and connection of the
appliance may make it hazardous for the health and life
of consumers. It may cause grievous and permanent
consequences, including but not limited to physical injuries and/or
death. Improper installation and connection of the appliance may
also lead to damage to the consumers' property /damage and/ or
destruction/, or to that of third persons, as a result of, but not limited
to flooding, explosion and/or fire.
Installation, connection to the main water and power supply, and
putting into operation must be carried out by certified electricians and
technical personnel certified in installation of this category of appliances,
who have obtained their license in the state where the installation and
commissioning of the appliance are carried out, and in compliance with
its local legislation.
10
Instructions for use and maintenance
1.
Mounting
We recommend the mounting of the device at close
proximity to locations where hot water is used, in
order to reduce heat losses during transportation.
In the event the device is mounted in a bathroom,
the selected location must exclude the possibility of
water spray contact from the showerhead or portable
showerhead attachment.
The appliance is affixed to a wall via the mounting
brackets attached to the unit's body (if the brackets are
not attached to the unit's body, they must be affixed in
place via the provided bolts). Two hooks are used for
suspending the appliance (min. Ø 10 mm) set firmly in
the wall (not included in the mounting set).
The mounting bracket's construction designed for
water heaters is universal and allows a distance
between the hooks of 220 to 310 mm (fig. 1).
In order to prevent injury to user and third persons in the
event of faults in the system for providing hot water, the
appliance must be mounted in premises outfitted with floor
hydro insulation and plumbing drainage. Don't place objects,
which are not waterproof under the appliance under any circumstances. In
the event of mounting the appliance in premises not outfitted with floor
hydro insulation, a protective tub with a plumbing drainage must be
placed under the appliance.
Notice: the set does not include a protective tub
and the user must select the same.
2.
Water heater connection to the pipe network.
Fig. 4 - Where: 1 - Inlet pipe; 2 - Safety valve; 3 -
reducing valve (for water main pressure > 0,6 MPa); 4 -
Stop valve; 5 - Funnel connected to the sewer network;
6 – Hose; 7 - Drain water tap.
Upon connecting the water heater to the water mains
you must consider the indicative color markings /rings/
affixed to the pipes: blue for cold /incoming/ water, red
for hot /outgoing/ water.
The mounting of the safety return-valve supplied with
the water heater is obligatory. The safety return-valve
must be mounted on the cold water supply pipe, in
observance of the direction arrow stamped on its body,
indicating the incoming water's direction. Additional
stopcocks must not be mounted between the safety
return-valve and the water heater.
Exception: If the local regulations (norms) require the
usage of another protection valve or mechanism (in
accordance with EN 1487 or EN 1489), then it must
be bought additionally. For mechanisms operating in
accordance with EN 1487 the announced operational
pressure must be no more than 0.7 MPa. For other
protection valves, the pressure at which they are
calibrated must be 0.1 MPa lower than the one marked
on the appliance's sign. In these cases the safety valve
which the appliance is supplied with should not be
used.
The presence of other /old/ safety return-valves may lead to a
breakdown of your appliance and they must be removed.
Other type of stopping armature is not allowed between the
protection return valve (the protective device) and the
appliance.
The attaching of the safety return-valve to threads longer
than 10 mm is not allowed, otherwise this may damage the
valve and poses danger for your appliance.