Electrical Connections - Hinkley HOVER FLUSH Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL CONNECTIONS

REMEMBER -Turn off the power! NOTE - Control must be installed within 30 feet of fan.
WARNINGS: Check to see that all connections are tight, including ground, and
that no bare wire is visible at the wire nuts, except for the ground wire.
CAUTION: To reduce the risk of electric shock, this fan must be installed with an
isolating wall control/switch.
1.
Insert the receiver into the ceiling mounting bracket with the flat side of the
receiver facing the ceiling. (Fig. 1) For best performance, make sure the
Black Antenna and WIFI Antenna, on the end of the receiver, remains
extended and not tangled with any of the electrical wires.
2. Make wire connections from the fan to the receiver unit. For this
step use the bundle of 5 wires on the receiver. (Fig. 2)
Connect the YELLOW fan wire to the YELLOW receiver wire.
Connect the GRAY fan wire to the GRAY receiver wire.
Connect the RED fan neutral wire to the RED receiver neutral wire.
Connect the WHITE fan neutral wire to the WHITE receiver neutral wire.
Connect the BLUE fan neutral wire to the BLUE receiver neutral wire.
3. Connect the wiring from the ceiling to the receiver unit. (Use the 2 wire
bundle on the receiver.) Secure with supplied wire nuts.
Connect the BLACK building supply wire to the BLACK receiver wire.
Connect the WHITE receiver neutral wire to the WHITE building neutral wire.
Connect the COPPER building ground wire to the 4 YELLOW/GREEN ground
wires from the fan and receiver.
Receiver
Fig. 1
BLK (AC IN)
WH (AC IN)
BLUE (For light)
WHITE
(For light)
Receiver
GRAY
YELLOW
RED
RED
YELLOW
GRAY
Fig. 2
©2019 Hinkley Lighting, Inc. | hinkley.com |
GROUND
Outlet box
Ceiling
Fan
07

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido