Instructions for fitting the filters and closing the purifier
Place and center the absolute filter in its right position,
1
and tighten all 4 locks to the maximum
Place the flap of the GRSystem filter below the side
2
guides, slide it along the guides fully and lower by 2 cm
Slide the prefilter fully along the lower guides
3
Place the metal panel in the correct position with the
4
label containing the serial number of the unit at the top.
Then tighten the 6 screws that will seal the unit
Position the white outer panel around 5 cm from the
5
bottom of the purifier, and then press it towards the
appliance until it adjusts, lowering them 5 cm until it is
in place
Please, contact Zonair3D
TM
replacements.
IMPORTANT: It is important that only original filters supplied
by Zonair3D
are used to ensure the desired result and correct
TM
operation of the unit. The use of filters not supplied by the
manufacturer will render the warranty null and void.
or your local distributor for
Managment of used filters
The filters from this purifier must be taken to your local green
point to be disposed of correctly, so that they can be managed
sustainably and do not create problems for the environment.
Disposal of old electrical appliances
European directive 2012/19/UE on Waste Electrical Equipment
(WEEE), specifies that old household electrical appliances
must not be disposed of with the normal unsorted municipal
waste.
The crossed out "wheeled bin" symbol reminds you of
your obligation to ispose of the appliance correctly.
Consumers must contact their local authorities or retailer for
information concerning the correct disposal of old appliances
and/or their batteries.
Air+ 300 S & 430 S · Page 25