Technical Data - Holex 08 1543_360 Manual Del Usuario

Tabla de contenido

Publicidad

10
6.4
READING THE BATTERY CAPACITY
Switch the lamp on.
en
▶ Read the remaining battery capacity from the state of charge display.
7.
FAULTS
Problem
Lamp fails to light
The state of charge display
fails to light up during the
charging process
8.
STORAGE
▶ Every three months, recharge the battery up to 50 % charged.
▶ Store the lamp at temperatures between -10 °C and + 40 °C.
9.
CLEANING
Clean the lamp with a damp cloth.
NOTICE
▶ Do not clean the lamp whilst it is being charged.
▶ Do not use any chemical cleaners, or cleaners containing alcohol or solvents.

10. TECHNICAL DATA

Lamp
Light beam
Usage on each charge
Color temperature
Dimensions (L×⌀)
Weight
Protection class
Ambient temperature in operation
Li-ion battery
Capacity
Charging time
Power supply unit supplied
Input
Output
Troubleshooting
▶ Charge the battery.
▶ Disconnect the lamp from the power supply,
reconnect the power supply unit.
▶ Contact Hoffmann Group customer service.
Irreparable damage to the lamp
due to improper cleaning
60 – 1000 lm
24 – 1.5 h
6000 – 7000 k
258 × 74 mm
470 g
IP 54, IK 07
-10 °C to +40 °C
3.7 V / 5200 mAh / 19.24 Wh
4.5 h
100 – 240 V / 50/60 Hz
5 V / 1A
www.hoffmann-group.com